Nilfisk-ALTO ATTIX 8 GALLON, 8 GALLON AE, 8 GALLON AS manual Troubleshooting, Fault, Cause, Remedy

Page 13

8 Troubleshooting

ATTIX 8 GALLON ATTIX 8 GALLON AS/E

english

Fault

‡ Motor does not start

Cause

>Fuse in mains plug has blown.

>Overload protection switch has tripped.

Remedy

Reset the fuse.

Switch off the vacuum cleaner and allow it to cool for approx. 5 minutes. If it can not be started again, contact the Alto service department.

Motor does not run in automatic mode1)

>Power tool is defective or not connected properly.

Check that the power tool works or that the plug is inserted correctly.

‡ Acoustic warning 1) is heard

>

Suction power selected with

(reduced suction power)

 

suction power control1) is too

 

 

low.

 

> Hose diameter does not

 

 

correspond to suction hose

 

 

diameter setting.

 

>

Clogged suction hose/

 

 

nozzle.

> Seal/tank rim between the upper section of the cleaner and the dirt tank is dirty/ defective.

Set suction power in accord- ance with section 4.2.3. "Suction power control".

Set suction hose diameter setting1) to correspond to hose diameter.

Clean suction hose/nozzle.

Clean/replace seal.

>Filter bag is full.

>Filter element is clogged.

See section 7.2.2 "Replacing the filter bag".

See section 4.4 "Cleaning the filter element" and 7.2.3 "Replacing the filter ele- ment".

No suction power during wet cleaning

>Tank is full (floater closes the suction opening).

Switch off the cleaner. Empty the tank.

‡ Voltage fluctuations

> Impedance of power supply

 

is too high.

Connect the cleaner to another socket closer to the fuse box. Voltage fluctua- tions over 7 % should not occur if the impedance at

the transfer point is 0.15 .

1)Option depending on model

13

Image 13
Contents Attix 8 Gallon Attix 8 Gallon AS/E Attix 8 Gallon Attix 8 Gallon AS/E Contents Important safety instructions Appliance socket Before starting the vacuum cleanerDuring use Electrical connectionsDescription Assembling the vacuum cleanerBefore starting PurposeConnecting power Ensure that the cleaner is switched offEnsure that the power tool is switched off OperationVacuum cleaner Switching onSwitch position Suction power control1Applications and techniques Cleaning the filter element1Only after sucking up dusts without a filter bag After finishing work Switching the vacuum Cleaner off and storagePicking up dry Substances Picking up liquids Do not pick up flammable LiquidsMaintenance plan MaintenanceReplacing the filter Never use the vacuum cleaner without a filterElement Fault TroubleshootingCause RemedyGuarantee CleanerFurther information Recycling the vacuumAccessories Technical dataSommaire Consignes de sécurité importantes Symboles de mise en gardeGénéralités Pour votre propre sécuritéPrise intégrée Pendant le service ElectricitéAffectation Avant la mise en serviceAssemblage de l’aspirateur Connexions Raccordement du tuyau flexible d’aspiration Commande / FonctionnementVeillez à ce que l’aspira- teur soit arrêté Raccordement d’unAS/E Mise en marche de l’aspirateur Position du commutateurDépoussiérage de la Domaines d’utilisation et méthodes de travailCartouche filtrante1 Après le travail Travaux de maintenance Vidage de la cuve à saletés Plan de maintenanceRemplacement du sac à poussières ’aspirez jamais sans filtre Dérangement Suppression de dérangementsCauses SuppressionDivers Caractéristiques techniques AccessoiresInternet