Baxi Potterton G.C.No 47 393 23 manual Installer Notification Guidelines, Scheme Members only

Page 3

Installer Notification Guidelines

Choose Building

Regulations Notification

Route

Competent Person's

Self Certification Scheme

Install and Commission this appliance to manufacturer's instructions

Complete the

Benchmark Checklist

If you notify via the ‘Gas Safe Register’, the register will issue the Building Regulations certificate on members’ behalf

Scheme Members only

Call ‘Gas Safe Register’ on: 0800 408 5577

or log onto:

www.gassaferegister.co.uk

within 10 days

You must ensure that the

certificate number issued by the ‘Gas Safe Register’ is written onto the Benchmark Checklist

‘Gas Safe Register’ will issue a Building Regulations Compliance Certificate to the property owner and inform the relevant LABC

Building Control

Contact your relevant Local Authority Building Control (LABC) who will arrange an inspection or contact a government approved inspector

Install and Commission this appliance to manufacturer's instructions

Complete the

Benchmark Checklist

LABC will record the data

and will issue a

certificate of compliance

© Baxi Heating UK Ltd 2011

3

Image 3
Contents Installation & Service Instructions 0086 Scheme Members only Installer Notification GuidelinesImportant Installation, Commissioning, Service & Repair LegislationCodes of Practice refer to the most recent version Technique Safe Manual HandlingGeneral PreparationContents Contents of Pack IntroductionDescription Layout General LayoutFrost Protection Mode Appliance OperationPump Protection Promax Combi 24, 28 Technical Data32.5 mm Condensate Drain 65 mm Dimensions and FixingsOrientation Tap RailBypass System DetailsInformation Central Heating CircuitSystem Filling and Pressurising Fig Expansion Vessel Central Heating onlyPressure Relief Valve Fig Domestic Hot Water Circuit Fig ShowersHard Water Areas Site Requirements LocationAt Least 1.5 7.2 Clearances Figs Electrical Supply Site RequirementVentilation of Compartments Gas SupplyCondensate Drain Flue terminal guard FlueHorizontal Flues Each fitting to aid assemblyFlue Options Horizontal Flue SystemsApart Vertical FluesTwin & Vertical Flue Systems 120mm MinFlue Accessories Key Accessory Size Code NoTelescopic Internal Flue Kit Twin Flue Duct Adaptor Twin Flue ConnectionAir Duct Connection Flue Duct Connection Boiler Adaptor Terminal Guard Fig Flue DimensionsFor Roof Terminals Flue TrimPlume Displacement Plume Displacement Kit FigMetres Ring Adaptor 5121368 28/33Determining Permissible Lengths Example30mm General Fitting NotesExtension and outlet. Secure using two of the screws Elbow to allow the flue to be installed as shown60Ø extension piece. It must be secured using two Using a suitable bit e.g mm, drill throughAfter considering the site requirements InstallationUnpacking & Initial Preparation FlushingTighten all the connections Fitting The BoilerFitting the Pressure Relief Discharge Pipe Fig Condensate Drain see sectionEnsure Elbow is fully Engaged into Boiler Fitting The FlueWall Thickness Waste Flue ElbowInner Flue Support Bracket 25mm Extension Cut EndEnsure Extension is fully engaged into Boiler Adaptor Making The Electrical Connections Preliminary Electrical ChecksTerminal Block Cover Cable Clamp Commissioning the Boiler CommissioningPressure Completion CompletionCase Front Panel Facia Panel Case Front Panel Facia Panel Securing Screws Servicing13 .1 Annual Servicing Annual Servicing Inspection10 ±1 Burner Sensing ElectrodeViewing Window Changing Components Igniter FigSpark and Sensing Electrodes Fig Gasket Venturi Injector Cover Gas Inlet Pipe Fan Collector Fan FigVenturi Fig Injector FigBurner Fig Insulation FigBurner Gasket Extension Piece Flue/Heat Exchanger Thermostat Sensor Fig Central Heating Temperature Sensor NTC FigSafety Thermostat Fig DHW Temperature Sensor NTC FigPump Head Only Fig Pump Complete FigAutomatic Air Vent Fig Hall Effect Sensor Fig Pressure Gauge FigsPlate Heat Exchanger Fig Diverter Valve Motor Unit & Assembly Fig14.22 P.C.B. Fig Selector Switch FigThrottle Adjustment Screw Gas Valve FigExpansion Vessel Fig Throttle Setting the Gas ValveSetting the Gas Valve CO2 check Flue Adaptor Test Point Plug Analyser ProbeElectrical Illustrated Wiring Diagram302 Short Parts ListShort Parts List 306Fault Finding Initial Fault Finding ChecksError Codes Pump runs Error 133 flashingGo to section ‘A’ Turn the selector switch to Reset position for 5 secondsOpen DHW tap fully Turn selector switch toError 133 flashing Go to section ‘I’ Turn Domestic Hot WaterReplace water PCB X3 connector terminals 3Switch terminal Fan jammed or faulty winding Replace PCBReplace gas valve Check wiring Viewing WindowReplace sensor or PCB E28 Gas at burnerReplace safety thermostat Replace PCB Is there 230V atReplace sensor Page Page Condensing Boilers only Service Record Brooks House, Coventry Road, Warwick. CV34 4LL

G.C.No 47 393 22, G.C.No 47 393 23, G.C.No 47 393 21 specifications

The Baxi Potterton range, specifically the models identified by G.C. No 47 393 21, G.C. No 47 393 23, and G.C. No 47 393 22, represents a robust selection of domestic heating solutions that cater to diverse consumer needs. Known for their reliability and efficiency, these boilers are designed with advanced technologies that ensure consistent performance and high levels of user satisfaction.

One of the primary features of these models is their compact design, allowing for flexibility in installation within various home environments. Whether placed in a kitchen, utility room, or cupboard, the space-saving configurations make them ideal for homeowners with limited installation areas.

These boilers utilize a high-efficiency heat exchanger that maximizes heating output while minimizing fuel consumption. This not only results in lower energy bills for consumers but also contributes positively towards reducing carbon footprints. The G.C. No 47 393 21, 47 393 22, and 47 393 23 models are known for their impressive Seasonal Efficiency Ratings, indicating superior energy efficiency, which is vital for compliance with modern building regulations.

In terms of technology, these models feature user-friendly digital displays that provide real-time information on system performance, making it easier for users to monitor and manage their home's heating needs. Additionally, some models come equipped with advanced control systems that allow homeowners to adjust settings remotely via smartphone applications, further enhancing convenience.

Safety is paramount in the design of Baxi Potterton boilers. Each unit is equipped with multiple safety features including built-in frost protection, pressure relief valves, and gas leak detection systems. This commitment to safety ensures peace of mind for users, knowing that their heating system is designed to operate securely.

Another significant characteristic of these models is their compatibility with renewable energy sources. They can work in conjunction with solar thermal systems and can be integrated into larger renewable setups, promoting sustainability in home heating.

In summary, the Baxi Potterton G.C. No 47 393 21, G.C. No 47 393 23, and G.C. No 47 393 22 models are a testament to modern engineering and design. With their emphasis on efficiency, safety, and convenience, they provide exceptional heating solutions for today's energy-conscious homeowners.