Baxi Potterton Baxi 5114767 Part Specifications and Manual

Page 49

306

426

315316

311

624419

422

400

415

302

421

420

 

503

504

17.0 Short Parts List

Short Parts List

 

Key

G.C.

Description

Manufacturers

 

No.

No.

 

Part No.

 

 

 

 

 

 

 

311

 

Fan

5121447

 

 

 

 

 

 

 

 

426

 

Motor 3way Valve

5132452

 

 

 

 

 

 

 

 

315

 

Igniter Electrode

720222801

 

 

 

 

 

 

 

 

316

 

Sensing Electrode

720222901

 

 

 

 

 

 

 

 

422

 

Gas Valve

720301001

 

 

 

 

 

 

 

 

404

 

Hall Effect Sensor

5114767

 

 

 

 

 

 

 

 

306

 

Burner 24

5122149

 

 

 

 

Burner 28

5122149

 

 

 

 

Burner 33

5114697

 

 

 

 

 

 

 

 

419

 

Water Pressure Switch

5114748

 

 

 

 

 

 

 

 

400

 

Plate Heat Exchanger 24

248048

 

 

 

 

Plate Heat Exchanger 28/33 5114708

 

 

 

 

 

 

 

415

 

Pump

248042

 

 

 

 

 

 

 

 

421

 

NTC Sensor

5114725

 

 

 

 

 

 

 

 

420

 

Overheat Thermostat

5114729

 

 

 

 

 

 

 

 

504

 

Pressure Gauge

248090

 

 

 

 

 

 

 

 

503

 

PCB 24

5121862

 

 

 

 

PCB 28

720043401

 

 

 

 

PCB 33

720795201

 

 

 

 

 

 

 

© Baxi Heating UK Ltd 2011

49

Image 49
Contents Installation & Service Instructions 0086 Scheme Members only Installer Notification GuidelinesLegislation Important Installation, Commissioning, Service & RepairCodes of Practice refer to the most recent version General Safe Manual HandlingPreparation TechniqueContents Introduction Contents of PackDescription Layout General LayoutAppliance Operation Frost Protection ModePump Protection Promax Combi 24, 28 Technical DataOrientation Dimensions and FixingsTap Rail 32.5 mm Condensate Drain 65 mmInformation System DetailsCentral Heating Circuit BypassExpansion Vessel Central Heating only System Filling and Pressurising FigPressure Relief Valve Fig Showers Domestic Hot Water Circuit FigHard Water Areas Location Site RequirementsAt Least 1.5 7.2 Clearances Figs Ventilation of Compartments Site RequirementGas Supply Electrical SupplyCondensate Drain Flue terminal guard FlueFlue Options Each fitting to aid assemblyHorizontal Flue Systems Horizontal FluesTwin & Vertical Flue Systems Vertical Flues120mm Min ApartKey Accessory Size Code No Flue AccessoriesTelescopic Internal Flue Kit Twin Flue Connection Twin Flue Duct AdaptorAir Duct Connection Flue Duct Connection Boiler Adaptor For Roof Terminals Flue DimensionsFlue Trim Terminal Guard FigPlume Displacement Kit Fig Plume DisplacementMetres Ring Adaptor Determining Permissible Lengths 28/33Example 512136830mm General Fitting Notes60Ø extension piece. It must be secured using two Elbow to allow the flue to be installed as shownUsing a suitable bit e.g mm, drill through Extension and outlet. Secure using two of the screwsUnpacking & Initial Preparation InstallationFlushing After considering the site requirementsFitting the Pressure Relief Discharge Pipe Fig Fitting The BoilerCondensate Drain see section Tighten all the connectionsWall Thickness Waste Fitting The FlueFlue Elbow Ensure Elbow is fully Engaged into Boiler25mm Extension Cut End Inner Flue Support BracketEnsure Extension is fully engaged into Boiler Adaptor Preliminary Electrical Checks Making The Electrical ConnectionsTerminal Block Cover Cable Clamp Commissioning the Boiler CommissioningPressure Completion CompletionCase Front Panel Facia Panel 13 .1 Annual Servicing ServicingAnnual Servicing Inspection Case Front Panel Facia Panel Securing ScrewsBurner Sensing Electrode 10 ±1Viewing Window Igniter Fig Changing ComponentsSpark and Sensing Electrodes Fig Venturi Fig Fan FigInjector Fig Gasket Venturi Injector Cover Gas Inlet Pipe Fan CollectorInsulation Fig Burner FigBurner Gasket Extension Piece Safety Thermostat Fig Central Heating Temperature Sensor NTC FigDHW Temperature Sensor NTC Fig Flue/Heat Exchanger Thermostat Sensor FigPump Complete Fig Pump Head Only FigAutomatic Air Vent Fig Hall Effect Sensor Fig Pressure Gauge FigsPlate Heat Exchanger Fig Diverter Valve Motor Unit & Assembly Fig14.22 P.C.B. Fig Selector Switch Fig Gas Valve Fig Throttle Adjustment Screw Expansion Vessel Fig Setting the Gas Valve CO2 check Setting the Gas ValveFlue Adaptor Test Point Plug Analyser Probe ThrottleElectrical Illustrated Wiring DiagramShort Parts List Short Parts List306 302Initial Fault Finding Checks Fault FindingError Codes Go to section ‘A’ Turn the selector switch to Error 133 flashingReset position for 5 seconds Pump runsError 133 flashing Go to section ‘I’ Turn selector switch toTurn Domestic Hot Water Open DHW tap fullySwitch terminal PCB X3 connector terminals 3Fan jammed or faulty winding Replace PCB Replace waterReplace sensor or PCB E28 Check wiring Viewing WindowGas at burner Replace gas valveReplace PCB Is there 230V at Replace safety thermostatReplace sensor Page Page Condensing Boilers only Service Record Brooks House, Coventry Road, Warwick. CV34 4LL