Baxi Potterton G.C.No 47 393 21, G.C.No 47 393 23, G.C.No 47 393 22 manual Condensing Boilers only

Page 58

Failure to install and commission according to the manufacturer’s instructions and complete this Benchmark Commissioning Checklist will invalidate the warranty. This does not affect the customer’s statutory rights.

If yes, and if required by the manufacturer, has a water scale reducer been fitted?

CONDENSING BOILERS ONLY

The condensate drain has been installed in accordance with the manufacturer’s instructions and/or BS5546/BS6798

Yes

 

 

 

 

 

 

 

 

 

 

If the condensate pipe terminates externally has the pipe diameter been increased and weatherproof insulation fitted?

Yes

 

 

 

 

 

 

58

Image 58
Contents Installation & Service Instructions 0086 Installer Notification Guidelines Scheme Members onlyLegislation Important Installation, Commissioning, Service & RepairCodes of Practice refer to the most recent version Preparation Safe Manual HandlingGeneral TechniqueContents Introduction Contents of PackDescription General Layout LayoutAppliance Operation Frost Protection ModePump Protection Technical Data Promax Combi 24, 28Tap Rail Dimensions and FixingsOrientation 32.5 mm Condensate Drain 65 mmCentral Heating Circuit System DetailsInformation BypassExpansion Vessel Central Heating only System Filling and Pressurising FigPressure Relief Valve Fig Showers Domestic Hot Water Circuit FigHard Water Areas Location Site RequirementsAt Least 1.5 7.2 Clearances Figs Gas Supply Site RequirementVentilation of Compartments Electrical SupplyCondensate Drain Flue Flue terminal guardHorizontal Flue Systems Each fitting to aid assemblyFlue Options Horizontal Flues120mm Min Vertical FluesTwin & Vertical Flue Systems ApartKey Accessory Size Code No Flue AccessoriesTelescopic Internal Flue Kit Twin Flue Connection Twin Flue Duct AdaptorAir Duct Connection Flue Duct Connection Boiler Adaptor Flue Trim Flue DimensionsFor Roof Terminals Terminal Guard FigPlume Displacement Kit Fig Plume DisplacementMetres Ring Adaptor Example 28/33Determining Permissible Lengths 5121368General Fitting Notes 30mmUsing a suitable bit e.g mm, drill through Elbow to allow the flue to be installed as shown60Ø extension piece. It must be secured using two Extension and outlet. Secure using two of the screwsFlushing InstallationUnpacking & Initial Preparation After considering the site requirementsCondensate Drain see section Fitting The BoilerFitting the Pressure Relief Discharge Pipe Fig Tighten all the connectionsFlue Elbow Fitting The FlueWall Thickness Waste Ensure Elbow is fully Engaged into Boiler25mm Extension Cut End Inner Flue Support BracketEnsure Extension is fully engaged into Boiler Adaptor Preliminary Electrical Checks Making The Electrical ConnectionsTerminal Block Cover Cable Clamp Commissioning Commissioning the BoilerPressure Completion CompletionCase Front Panel Facia Panel Annual Servicing Inspection Servicing13 .1 Annual Servicing Case Front Panel Facia Panel Securing ScrewsBurner Sensing Electrode 10 ±1Viewing Window Igniter Fig Changing ComponentsSpark and Sensing Electrodes Fig Injector Fig Fan FigVenturi Fig Gasket Venturi Injector Cover Gas Inlet Pipe Fan CollectorInsulation Fig Burner FigBurner Gasket Extension Piece DHW Temperature Sensor NTC Fig Central Heating Temperature Sensor NTC FigSafety Thermostat Fig Flue/Heat Exchanger Thermostat Sensor FigPump Complete Fig Pump Head Only FigAutomatic Air Vent Fig Pressure Gauge Figs Hall Effect Sensor FigDiverter Valve Motor Unit & Assembly Fig Plate Heat Exchanger FigSelector Switch Fig 14.22 P.C.B. FigGas Valve Fig Throttle Adjustment ScrewExpansion Vessel Fig Flue Adaptor Test Point Plug Analyser Probe Setting the Gas ValveSetting the Gas Valve CO2 check ThrottleIllustrated Wiring Diagram Electrical306 Short Parts ListShort Parts List 302Initial Fault Finding Checks Fault FindingError Codes Reset position for 5 seconds Error 133 flashingGo to section ‘A’ Turn the selector switch to Pump runsTurn Domestic Hot Water Turn selector switch toError 133 flashing Go to section ‘I’ Open DHW tap fullyFan jammed or faulty winding Replace PCB PCB X3 connector terminals 3Switch terminal Replace waterGas at burner Check wiring Viewing WindowReplace sensor or PCB E28 Replace gas valveReplace PCB Is there 230V at Replace safety thermostatReplace sensor Page Page Condensing Boilers only Service Record Brooks House, Coventry Road, Warwick. CV34 4LL

G.C.No 47 393 22, G.C.No 47 393 23, G.C.No 47 393 21 specifications

The Baxi Potterton range, specifically the models identified by G.C. No 47 393 21, G.C. No 47 393 23, and G.C. No 47 393 22, represents a robust selection of domestic heating solutions that cater to diverse consumer needs. Known for their reliability and efficiency, these boilers are designed with advanced technologies that ensure consistent performance and high levels of user satisfaction.

One of the primary features of these models is their compact design, allowing for flexibility in installation within various home environments. Whether placed in a kitchen, utility room, or cupboard, the space-saving configurations make them ideal for homeowners with limited installation areas.

These boilers utilize a high-efficiency heat exchanger that maximizes heating output while minimizing fuel consumption. This not only results in lower energy bills for consumers but also contributes positively towards reducing carbon footprints. The G.C. No 47 393 21, 47 393 22, and 47 393 23 models are known for their impressive Seasonal Efficiency Ratings, indicating superior energy efficiency, which is vital for compliance with modern building regulations.

In terms of technology, these models feature user-friendly digital displays that provide real-time information on system performance, making it easier for users to monitor and manage their home's heating needs. Additionally, some models come equipped with advanced control systems that allow homeowners to adjust settings remotely via smartphone applications, further enhancing convenience.

Safety is paramount in the design of Baxi Potterton boilers. Each unit is equipped with multiple safety features including built-in frost protection, pressure relief valves, and gas leak detection systems. This commitment to safety ensures peace of mind for users, knowing that their heating system is designed to operate securely.

Another significant characteristic of these models is their compatibility with renewable energy sources. They can work in conjunction with solar thermal systems and can be integrated into larger renewable setups, promoting sustainability in home heating.

In summary, the Baxi Potterton G.C. No 47 393 21, G.C. No 47 393 23, and G.C. No 47 393 22 models are a testament to modern engineering and design. With their emphasis on efficiency, safety, and convenience, they provide exceptional heating solutions for today's energy-conscious homeowners.