LG Electronics WG1805RY6 Disassembly, Mechanical Parts, Front Grille, Cabinet, Control Box

Page 16

Disassembly

Disassembly

— Before the following disassembly, CONTROL BOX set to OFF and disconnect the power cord.

MechanicalParts

1.Front Grille

1.Open the lnlet grille upward .

2.Remove the screw that fastens the front grille.

3.Pull the front grille from the right side.

4.Remove the front grille.

5.Re-install the component by referring to the removal procedure, above.(See Figure 17)

NOTICE Mark " "of inlet grille means opening d irection.

2.Cabinet

1.After disassembling the FRONT GRILLE, remove the 2 screws that fasten the cabinet at both sides.

2.Remove the 2 screws that fasten the cabinet at back.

3.Pull the base pan forward. (See Figure 18)

4.Remove the cabinet.

5.Re-install the component by referring to the removal procedure, above.

3.Control Box

1.Remove the front grille. (Refer to section 17)

2.Remove the cabinet. (Refer to section 18)

3.Remove the 2 screws that fasten the control box cover.

4.Remove two housings that connect compressor wire and motor wire in the control box.

5.Discharge the capacitor by placing a 20,000 ohm resistor across the capacitor terminals.

6.Remove the 2 screws that fasten the control box.

7.Pull the control box forward completely.

8.Re-install the components by referring to the removal procedure, above. (See Figure 19)

(Refer to the circuit diagram found on page 23 in this manual and on the control box.)

Figure 17

Figure 18

Figure 19

15Room Air Conditioner

Image 16
Contents LG Room Air Conditioner Table of Contents Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk or fire or electric shock Symbols Used in this Manual DimensionsOutside Dimensions Product Specifications 800/1,850 760/2,710 Installation Installation CheckHow to Secure the Drain Pipe Select the Best LocationInstallation Kits Contents Window RequirementsSuggested Tool Requirements Preparation of ChassisCabinet Installation Installation Features OperationControl Locations Function of Controls Cooling Only ModelWG2405RY6, WG2405RY6 Cooling Only Model with Remote Control and Touch TypeWG2405RY6 Disassembly Mechanical PartsFront Grille CabinetAir Handling Parts Cover at the topBlower FanElectrical Parts ShroudMotor CompressorPower Cord CapacitorThermistor Synchronous MotorEvaporator Refrigerating CycleCapillary Tube Disassembly Pulling Vacuum Diagram CN-TH1Wiring Diagram Model WG1805RY6 / WG2405RY6Main P.W.B Assembly Display P.W.B Assembly Components LocationTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electrical Parts Troubleshooting Guide Possible TroubleIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July