LG Electronics RAD-183A, WG1805RY6, WG2405RY6, RAD-243A Electrical Parts, Shroud, Motor, Compressor

Page 18

Disassembly

6. Shroud

1. Remove the fan. (Refer to section 21)

2. Remove the screw that fastens the shroud.

3. Remove the shroud. (See Figure 24)

4. Re-install the component by referring to the removal procedure, above.

Figure 24

Electrical Parts

7. Motor

1. Remove the cabinet. (Refer to section 18)

2. Remove the cover control and disconnect a wire housing in control box. (Refer to section 19)

3. Remove the blower. (Refer to section 21)

4. Remove the fan. (Refer to section 22)

5. Remove the 4 screws which fasten the motor. (See Figure. 25)

6. Remove the motor.

7. Re-install the components by referring to the

removal procedure, above.

Figure 25

8.Compressor

1.Remove the cabinet. (Refer to section 18)

2.Discharge the refrigerant system using FreonTM Recovery System.

If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting

 

the FreonTM . Leave the valve in place after

 

 

servicing the system.

 

3.

Disconnect the 3 leads from the compressor.

 

4.

After purging the unit completely, unbrace the suc-

 

 

tion and discharge tubes at the compressor con-

 

 

nections.

 

5.

Remove the 3 nuts and the 3 washers which fas-

 

 

ten the compressor.

Figure 26

6.

Remove the compressor. (See Figure 26)

 

7.Re-instill the components by referring to the removal procedure, above.

17Room Air Conditioner

Image 18
Contents LG Room Air Conditioner Table of Contents Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk or fire or electric shock Dimensions Symbols Used in this ManualOutside Dimensions Product Specifications 800/1,850 760/2,710 How to Secure the Drain Pipe InstallationInstallation Check Select the Best LocationInstallation Kits Contents Window RequirementsSuggested Tool Requirements Preparation of ChassisCabinet Installation Installation Control Locations Function of Controls FeaturesOperation Cooling Only ModelCooling Only Model with Remote Control and Touch Type WG2405RY6, WG2405RY6WG2405RY6 Front Grille DisassemblyMechanical Parts CabinetBlower Air Handling PartsCover at the top FanMotor Electrical PartsShroud CompressorThermistor Power CordCapacitor Synchronous MotorRefrigerating Cycle EvaporatorCapillary Tube Disassembly Pulling Vacuum Diagram CN-TH1Wiring Diagram Model WG1805RY6 / WG2405RY6Main P.W.B Assembly Display P.W.B Assembly Components LocationTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electrical Parts Troubleshooting Guide Possible TroubleIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July