LG Electronics RAD-243A, WG1805RY6, WG2405RY6, RAD-183A service manual 800/1,850

Page 7

Specfications

Product Specifications

Table -1

ITEMS

 

MODELS

RAD-183A

 

 

 

 

 

POWER SUPPLY

 

 

1Ø, 208/230V, 60Hz

 

 

 

COOLING CAPACITY

 

17,500/18,000

 

 

 

 

INPUT

 

 

1,800/1,850

 

 

 

RUNNING CURRENT

 

9.7

 

 

REFRIGERANT (R-22) CHARGE(g)

720g(25.4oz)

 

 

 

OPERATING

INDOOR(°C)

27(DB),19(WB)

 

 

 

TEMPERATURE

OUTDOOR(°C)

35(DB),24(WB)

 

 

 

 

EVAPORATOR

 

 

2 ROW 15 STACKS

 

 

 

LOUVERED-FIN TYP

 

 

 

 

CONDENSER

 

 

2 ROW 19 STACKS,LOUVERED-FIN TYPE

 

 

 

L-BENDING TYPE

FAN, INDOOR

 

 

TURBO

FAN, OUTDOOR

 

 

PROPELLER TYPE FAN WITH SLINGER-RING

 

 

FAN SPEEDS, FAN/COOLING

3/3

 

 

 

 

FAN MOTOR

 

 

6 POLES

 

 

 

OPERATION CONTROL

 

WIRELESS REMOCN

 

 

 

ROOM TEMP. CONTROL

 

THERMISTOR

 

 

AIR DIRECTION CONTROL

VERTICAL LOUVER(RIGHT & LEFT)

 

 

 

 

 

 

 

HORIZONTAL LOUVER(UP & DOWN)

CONSTRUCTION

 

 

SLIDE IN-OUT CHASSIS

PROTECTOR

COMPRESSOR

INTERNAL OVERLOAD PROTECTOR

 

 

 

 

FAN MOTOR

INTERNAL THERMAL PROTECTOR

 

 

 

 

POWER CORD

 

 

3 WIRE WITH GROUNDING

 

 

 

 

 

 

 

CORD-CONNECTED TYPE(ATTATCHMENT PLUG:OPTION)

DRAIN SYSTEM

 

 

DRAIN PIPE OR SPLASHED BY FAN SLINGER

NET WEIGHT

 

(lbs/kg)

130/60

 

 

 

OUTSIDE DIMENSION

(inch)

26 x 16 27/32 x 26 9/16

(W x H x D)

 

(mm)

660 x 428 x 675

7Room Air Conditioner

Image 7
Contents LG Room Air Conditioner Table of Contents Be sure not to do Be sure to follow the instruction Safety PrecautionsThere is risk or fire or electric shock Symbols Used in this Manual DimensionsOutside Dimensions Product Specifications 800/1,850 760/2,710 Select the Best Location InstallationInstallation Check How to Secure the Drain PipeWindow Requirements Installation Kits ContentsPreparation of Chassis Suggested Tool RequirementsCabinet Installation Installation Cooling Only Model FeaturesOperation Control Locations Function of ControlsWG2405RY6, WG2405RY6 Cooling Only Model with Remote Control and Touch TypeWG2405RY6 Cabinet DisassemblyMechanical Parts Front GrilleFan Air Handling PartsCover at the top BlowerCompressor Electrical PartsShroud MotorSynchronous Motor Power CordCapacitor ThermistorEvaporator Refrigerating CycleCapillary Tube Disassembly Pulling Vacuum CN-TH1 DiagramModel WG1805RY6 / WG2405RY6 Wiring DiagramComponents Location Main P.W.B Assembly Display P.W.B AssemblyPiping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Possible Trouble Electrical Parts Troubleshooting GuideIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Complaint Cause Remedy Room Air Conditioner Voltage LimitsTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July