LG Electronics RAD-243A, WG1805RY6, WG2405RY6 Suggested Tool Requirements, Preparation of Chassis

Page 11

Installation

SuggestedTool Requirements

PREPARATION OF CHASSIS

1.Remove the screws which fasten the cabinet at both sides and at the back.

2.Slide the unit out from the cabinet by gripping the base pan handle and pulling forward while bracing the cabinet.

3.Cut the window sash seal to the proper length. Peel off the backing and attach the Foam-PE to the underside of the window sash.

Shipping screws

Figure 2

Figure 3

4.Remove the backing from Foam-PE with 3 holes and attach it to the bottom of the Top retainer bar.

5.Attach the Top retainer bar on the top of the cabinet with 3 screws (Type A).

 

Top retainer bar

Foam-PE

Foam-PE

Figure 4

 

 

6.

Insert the Frame guides into the bottom of the cabi-

 

 

 

 

net.

Top retainer bar

 

 

7.

Insert the Frame Curtain into the Top retainer bar

 

 

 

 

and Frame guides.

 

 

 

8.

Fasten the curtains to the unit with 10 screws

 

 

 

 

(Type A) at both sides.

Screw

 

 

 

 

(Type A)

Screw(Type A)

 

 

Frame guide

Figure 5

 

 

Service Manual

10

Image 11
Contents LG Room Air Conditioner Table of Contents Be sure not to do Be sure to follow the instruction Safety PrecautionsThere is risk or fire or electric shock Outside Dimensions DimensionsSymbols Used in this Manual Product Specifications 800/1,850 760/2,710 Select the Best Location InstallationInstallation Check How to Secure the Drain PipeWindow Requirements Installation Kits ContentsPreparation of Chassis Suggested Tool RequirementsCabinet Installation Installation Cooling Only Model FeaturesOperation Control Locations Function of ControlsWG2405RY6 Cooling Only Model with Remote Control and Touch TypeWG2405RY6, WG2405RY6 Cabinet DisassemblyMechanical Parts Front GrilleFan Air Handling PartsCover at the top BlowerCompressor Electrical PartsShroud MotorSynchronous Motor Power CordCapacitor ThermistorCapillary Tube Refrigerating CycleEvaporator Disassembly Pulling Vacuum CN-TH1 DiagramModel WG1805RY6 / WG2405RY6 Wiring DiagramComponents Location Main P.W.B Assembly Display P.W.B AssemblyPiping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Possible Trouble Electrical Parts Troubleshooting GuideIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Complaint Cause Remedy Room Air Conditioner Voltage LimitsTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July