LG Electronics WG2405RY6, WG1805RY6, RAD-183A Air Handling Parts, Cover at the top, Blower, Fan

Page 17

Disassembly

Air HandlingParts

4. Cover (at the top)

1. Remove the front grille. (Refer to section 17)

2. Remove the cabinet. (Refer to section 18)

3. Remove 11 screws which fasten the brace and covers.

4. Remove the covers and the brace. (See Fig. 20)

5. Re-install the components by referring to the removal procedure, above.

Figure 20

5.Blower

1.Remove the cover. (Refer to section 20)

2.Remove the 3 screws which fasten the evaporator at the left side and the top side.

3.Move the evaporator sideward carefully.

4.Remove the orifice from the air guide carefully.

5.Remove the clamp which secures the blower with plier. (See Fig. 21)

6.Remove the blower with plier or your hand without touching blades. (See Fig. 22)

7.Re-install the components by referring to the removal procedure, above.

6.Fan

1.Remove the cabinet. (Refer to section 18)

2.Remove the brace and shroud cover. (Refer to section 20)

3.Remove the 5 screws which fasten the condenser.

4.Move the condenser sideways carefully.

5.Remove the clamp which secures the fan.

6.Remove the fan. (See Figure 23)

7.Re-install the components by referring to the removal procedure, above.

Figure 21

Figure 22

Figure 23

Service Manual 16

Image 17
Contents LG Room Air Conditioner Table of Contents Be sure not to do Be sure to follow the instruction Safety PrecautionsThere is risk or fire or electric shock Outside Dimensions DimensionsSymbols Used in this Manual Product Specifications 800/1,850 760/2,710 Installation Check InstallationHow to Secure the Drain Pipe Select the Best LocationWindow Requirements Installation Kits ContentsPreparation of Chassis Suggested Tool RequirementsCabinet Installation Installation Operation FeaturesControl Locations Function of Controls Cooling Only ModelWG2405RY6 Cooling Only Model with Remote Control and Touch TypeWG2405RY6, WG2405RY6 Mechanical Parts DisassemblyFront Grille CabinetCover at the top Air Handling PartsBlower FanShroud Electrical PartsMotor CompressorCapacitor Power CordThermistor Synchronous MotorCapillary Tube Refrigerating CycleEvaporator Disassembly Pulling Vacuum CN-TH1 DiagramModel WG1805RY6 / WG2405RY6 Wiring DiagramComponents Location Main P.W.B Assembly Display P.W.B AssemblyPiping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Possible Trouble Electrical Parts Troubleshooting GuideIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Complaint Cause Remedy Room Air Conditioner Voltage LimitsTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July