LG Electronics RAD-183A, WG1805RY6, WG2405RY6, RAD-243A service manual Product Specifications

Page 6

Specfications

Product Specifications

Table -1

ITEMS

 

MODELS

WG1805RY6

WG2405RY7

 

 

 

 

 

 

POWER SUPPLY

 

 

1Ø, 208/230V, 60Hz

 

 

 

 

 

COOLING CAPACITY

 

17,500/18,000

23,500/23,800

 

 

 

 

 

INPUT

 

 

1,800/1,850

2,760/2,800

 

 

 

 

RUNNING CURRENT

 

9.7

8.5

 

 

 

REFRIGERANT (R-22) CHARGE(g)

720g(25.4oz)

830g(29.3oz)

 

 

 

 

OPERATING

INDOOR(°C)

27(DB),19(WB)

 

 

 

 

 

TEMPERATURE

OUTDOOR(°C)

35(DB),24(WB)

 

 

 

 

 

 

EVAPORATOR

 

 

2 ROW 15 STACKS

 

 

 

 

LOUVERED-FIN TYP

 

 

 

 

 

CONDENSER

 

 

2 ROW 19 STACKS,LOUVERED-FIN TYPE

 

 

 

L-BENDING TYPE

 

FAN, INDOOR

 

 

TURBO

 

FAN, OUTDOOR

 

 

PROPELLER TYPE FAN WITH SLINGER-RING

 

 

 

FAN SPEEDS, FAN/COOLING

3/3

 

 

 

 

 

 

FAN MOTOR

 

 

6 POLES

 

 

 

 

 

OPERATION CONTROL

 

WIRELESS REMOCN

 

 

 

 

 

ROOM TEMP. CONTROL

 

THERMISTOR

 

 

 

AIR DIRECTION CONTROL

VERTICAL LOUVER(RIGHT & LEFT)

 

 

 

 

 

 

 

HORIZONTAL LOUVER(UP & DOWN)

CONSTRUCTION

 

 

SLIDE IN-OUT CHASSIS

PROTECTOR

COMPRESSOR

INTERNAL OVERLOAD PROTECTOR

 

 

 

 

FAN MOTOR

INTERNAL THERMAL PROTECTOR

 

 

 

 

POWER CORD

 

 

3 WIRE WITH GROUNDING

 

 

 

 

 

 

 

CORD-CONNECTED TYPE(ATTATCHMENT PLUG:OPTION)

DRAIN SYSTEM

 

 

DRAIN PIPE OR SPLASHED BY FAN SLINGER

NET WEIGHT

 

(lbs/kg)

130/60

147.7/67

 

 

 

 

OUTSIDE DIMENSION

(inch)

26 x 16 27/32 x 26 9/16

26 x16 27/32 x 30 5/16

(W x H x D)

 

(mm)

660 x 428 x 675

660 x 428 x 675

6Room Air Conditioner

Image 6
Contents LG Room Air Conditioner Table of Contents Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk or fire or electric shock Dimensions Symbols Used in this ManualOutside Dimensions Product Specifications 800/1,850 760/2,710 How to Secure the Drain Pipe InstallationInstallation Check Select the Best LocationInstallation Kits Contents Window RequirementsSuggested Tool Requirements Preparation of ChassisCabinet Installation Installation Control Locations Function of Controls FeaturesOperation Cooling Only ModelCooling Only Model with Remote Control and Touch Type WG2405RY6, WG2405RY6WG2405RY6 Front Grille DisassemblyMechanical Parts CabinetBlower Air Handling PartsCover at the top FanMotor Electrical PartsShroud CompressorThermistor Power CordCapacitor Synchronous MotorRefrigerating Cycle EvaporatorCapillary Tube Disassembly Pulling Vacuum Diagram CN-TH1Wiring Diagram Model WG1805RY6 / WG2405RY6Main P.W.B Assembly Display P.W.B Assembly Components LocationTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electrical Parts Troubleshooting Guide Possible TroubleIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July