LG Electronics WG2405RY6, WG1805RY6 Select the Best Location, Installation Check, Optional

Page 9

Installation

Installation

SelecttheBest Location

1.To prevent vibration and noise, make sure the unit is installed securely and firmly.

2.Install the unit where the sunlight does not shine directly on the unit.

3.The outside of the cabinet must extend outward for at least 30cm and there should be no obstacles, such as a fence or wall, within 50cm from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.

COOLED AIR

75~15cm

AWNING FENCE

HEAT

RADIATION

ABOUT 10~15mm

Over 50cm

Figure 1

4.Install the unit a little slanted so the back is slightly lower than the front (about 10~15mm). This will help force con- densed water to the outside.

5.Install the unit from the bottom about 75~150cm above the floor level.

Installation Check

The setting conditions must be checked prior to initial starting.

The following items are especially important checking points when the installation is finished.

1.Grounding wire (Green or Green and Yellow) is provided in the power cord. The green wire must be grounded.

2.Connect to a single-outlet 15A circuit. (or 20A circuit for Electric Heater Model)

3.To avoid vibration or noise, make sure the air conditioner is installed securely.

4 Avoid placing furniture or draperies in front of the air inlet and outlet.

How to Secure the Drain Pipe

 

 

In humid weather, excess water may cause the BASE PAN to overflow. To drain

 

 

the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of

Drain pipe

 

the BASE PAN. Press the drain pipe into the hole by pushing down and away from

 

the fins to avoid injury.

 

Drain cap

Optional

 

 

1. Install the drain pan over the corner of the cabinet where you removed the

CABINET

SCREW

plug with 4 (or 2) screws.

 

 

2. Connect the drain hose to the outlet located at the bottom of the drain pan.

DRAIN

Fig. 1

You can purchase the drain hose or tubing locally to satisfy your particular

DRAIN HOSE

PAN

needs. (Drain hose is not supplied).

 

 

 

3. Select the most appropriate connection from among the following figures (by

 

considering the hole of the unit) to fit drain pan to your own unit.

 

Fig. 3

Fig. 2

Fig. 4

Service Manual 8

Image 9
Contents LG Room Air Conditioner Table of Contents Be sure not to do Be sure to follow the instruction Safety PrecautionsThere is risk or fire or electric shock Dimensions Symbols Used in this ManualOutside Dimensions Product Specifications 800/1,850 760/2,710 Installation Check InstallationHow to Secure the Drain Pipe Select the Best LocationWindow Requirements Installation Kits ContentsPreparation of Chassis Suggested Tool RequirementsCabinet Installation Installation Operation FeaturesControl Locations Function of Controls Cooling Only ModelCooling Only Model with Remote Control and Touch Type WG2405RY6, WG2405RY6WG2405RY6 Mechanical Parts DisassemblyFront Grille CabinetCover at the top Air Handling PartsBlower FanShroud Electrical PartsMotor CompressorCapacitor Power CordThermistor Synchronous MotorRefrigerating Cycle EvaporatorCapillary Tube Disassembly Pulling Vacuum CN-TH1 DiagramModel WG1805RY6 / WG2405RY6 Wiring DiagramComponents Location Main P.W.B Assembly Display P.W.B AssemblyPiping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Possible Trouble Electrical Parts Troubleshooting GuideIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Complaint Cause Remedy Room Air Conditioner Voltage LimitsTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July