LG Electronics WG1805RY6, WG2405RY6 Possible Trouble 6 Remote controller does not operate

Page 32

Troubleshooting Guide

Possible Trouble 6 Remote controller does not operate.

Is the voltage of Battery

NO

about over 2.3V?

 

 

YES

 

 

 

Is the voltage No.16

NO

of CN-DISP on Main PCB

 

Ass'y DC 5V?

 

 

YES

 

 

 

Is the connection of

NO

CN-DISP all right?

 

YES

• Exchange Receiver Ass'y.

• Exchange the battery.

• Check the PCB pattern.

Connect connector to CN-DISP exactly.

Possible Trouble 7 It displays abnormally on display PCB Ass'y.

NO

Is the IC01G all right?

 

YES

 

 

NO

 

Is the connection of

NO

CN-DISP all right?

 

 

YES

 

 

 

Does the

NO

Q01G~Q04G operate normally

 

on main PCB Ass'y?

 

YES

Exchange the display PCB Ass'y.

• Exchange IC01G.

• Connect connector to CN-DISP exactly.

• Exchange Q01G-Q04G.

31Room Air Conditioner

Image 32
Contents LG Room Air Conditioner Table of Contents Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk or fire or electric shock Outside Dimensions DimensionsSymbols Used in this Manual Product Specifications 800/1,850 760/2,710 Installation Installation CheckHow to Secure the Drain Pipe Select the Best LocationInstallation Kits Contents Window RequirementsSuggested Tool Requirements Preparation of ChassisCabinet Installation Installation Features OperationControl Locations Function of Controls Cooling Only ModelWG2405RY6 Cooling Only Model with Remote Control and Touch TypeWG2405RY6, WG2405RY6 Disassembly Mechanical PartsFront Grille CabinetAir Handling Parts Cover at the topBlower FanElectrical Parts ShroudMotor CompressorPower Cord CapacitorThermistor Synchronous MotorCapillary Tube Refrigerating CycleEvaporator Disassembly Pulling Vacuum Diagram CN-TH1Wiring Diagram Model WG1805RY6 / WG2405RY6Main P.W.B Assembly Display P.W.B Assembly Components LocationTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electrical Parts Troubleshooting Guide Possible TroubleIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July