Possible Trouble 1

The unit does not operate.

Is the Trans output power

NO

 

 

 

 

 

 

• Check the Fuse.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Check the wiring diagram.

 

AC 220V?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

NO

 

 

 

 

Is the Trans output power

Is shorted the Trans. output?

 

 

• Check the Main

 

 

 

 

 

 

 

about AC 14V?

 

 

 

 

 

 

 

PCB pattern.

 

 

YES

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Exchange the Trans.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is output Voltage of IC01D

NO

 

 

 

 

 

 

• Exchange D02D~D05D.

 

 

 

 

 

 

 

• Exchange IC01D.

 

DC 12V?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

Is output Voltage of IC02D

 

 

 

 

 

 

• Exchange IC02D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC 5V?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the reset circuit all right?

NO

(The No.16 of

 

Micom is 5V.)

 

 

YES

 

 

 

 

 

 

Is the

connection between NO Main and Display

all right?

YES

NO

Is the voltage No.20 of Micom

DC 5V?

• Exchange IC01A, C02A.

Connect connector exactly.

Check the PCB pattern.

YES

Exchange Main PCB Ass'y.

Service Manual 28

Image 29
Contents LG Room Air Conditioner Table of Contents Be sure not to do Be sure to follow the instruction Safety PrecautionsThere is risk or fire or electric shock Outside Dimensions DimensionsSymbols Used in this Manual Product Specifications 800/1,850 760/2,710 Installation Check InstallationHow to Secure the Drain Pipe Select the Best LocationWindow Requirements Installation Kits ContentsPreparation of Chassis Suggested Tool RequirementsCabinet Installation Installation Operation FeaturesControl Locations Function of Controls Cooling Only ModelWG2405RY6 Cooling Only Model with Remote Control and Touch TypeWG2405RY6, WG2405RY6 Mechanical Parts DisassemblyFront Grille CabinetCover at the top Air Handling PartsBlower FanShroud Electrical PartsMotor CompressorCapacitor Power CordThermistor Synchronous MotorCapillary Tube Refrigerating CycleEvaporator Disassembly Pulling Vacuum CN-TH1 DiagramModel WG1805RY6 / WG2405RY6 Wiring DiagramComponents Location Main P.W.B Assembly Display P.W.B AssemblyPiping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Possible Trouble Electrical Parts Troubleshooting GuideIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Complaint Cause Remedy Room Air Conditioner Voltage LimitsTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July