LG Electronics RAD-183A, WG1805RY6 Operation, Features, Control Locations Function of Controls

Page 14

Operation

Operation

Features

Designed for COOLING ONLY.

Powerful and whispering cooling.

Slide-in and slide-out chassis for the simple instal- lation and service.

Side air-intake, side cooled-air discharge.

Built-in adjustable THERMOSTAT

Washable one-touch filter

Compact size

Reliable and efficient rotary compressor

ControlLocationsFunctionofControls

1. Cooling Only Model

• VENTILATION

The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When a fresh air is necessary in the room, set the ventilation lever OPEN position.

The damper is opened and room air is exhausted.

NOTICE Before using the ventilation feature, make the lever, as shown. First, pull down part to horizontal line with part .

CLOSE VENT OPEN

• THERMOSTAT

Thermostat will automatically control the temperature of the room. Select a higher number for a cooler tem- perature in the room. The temperature is selected by positioning the knob to the desired position.

The 5 or 6 position is a normal setting for average conditions.

• OPERATION

OFF

: Turns the air conditioner off.

MED FAN

: Permits the medium fan speed operation

 

without cooling.

LOW FAN

: Permits the low fan speed operation

 

without cooling.

HIGH COOL : Permits cooling with the high fan speed operation.

MED COOL : Permits cooling with the medium fan speed operation.

LOW COOL : Permits cooling with the low fan speed operation.

• AUTO SWING

ON

: Air swing is operated while OPERATION knob is

 

set to the COOL position.

OFF

: Stops the operation of air swing.

 

Thermostat

Auto Swing

 

Operation

 

5

 

Off

 

 

 

4

6

 

Med

High

 

Off

On

 

 

 

Fan

Cool

3

7

 

 

 

2

8

 

 

 

1

9

 

Low

Med

 

Fan

Cool

Low Cool

13Room Air Conditioner

Image 14
Contents LG Room Air Conditioner Table of Contents Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk or fire or electric shock Outside Dimensions DimensionsSymbols Used in this Manual Product Specifications 800/1,850 760/2,710 How to Secure the Drain Pipe InstallationInstallation Check Select the Best LocationInstallation Kits Contents Window RequirementsSuggested Tool Requirements Preparation of ChassisCabinet Installation Installation Control Locations Function of Controls FeaturesOperation Cooling Only ModelWG2405RY6 Cooling Only Model with Remote Control and Touch TypeWG2405RY6, WG2405RY6 Front Grille DisassemblyMechanical Parts CabinetBlower Air Handling PartsCover at the top FanMotor Electrical PartsShroud CompressorThermistor Power CordCapacitor Synchronous MotorCapillary Tube Refrigerating CycleEvaporator Disassembly Pulling Vacuum Diagram CN-TH1Wiring Diagram Model WG1805RY6 / WG2405RY6Main P.W.B Assembly Display P.W.B Assembly Components LocationTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electrical Parts Troubleshooting Guide Possible TroubleIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July