Disassembly

RefrigeratingCycle

CAUTION: Discharge the refrigerant system using a FreonTM Recovery

System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system.

13. Condenser

1.Remove the cabinet. (Refer to section 18)

2.Remove the 4 screws that fasten the brace.(Refer to section 20)

3.Remove the 5 screws that fasten the condenser and shroud.

4.After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.

5.Remove the condenser.

6.Re-install the component by referring to notes. (See Figure 31)

14. evaporator

1.Remove the cabinet. (Refer to section 18)

2.Remove the 2 screws that fasten the evaporator.

3.Move the evaporator sideways carefully. (Refer to section 20)

4.After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections.

5.Remove the evaporator.

6.Re-install the component by referring to notes. (See Figure 32)

15. Capillary Tube

1.Remove the cabinet. (Refer to section 18)

2.After discharging the refrigerant completely, unbraze the interconnecting tube at the capillary tube.(See caution above)

3.Remove the capillary tube.

4.Re-install the component by referring to notes.

Figure 31

Figure 32

19Room Air Conditioner

Image 20
Contents LG Room Air Conditioner Table of Contents Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk or fire or electric shock Outside Dimensions DimensionsSymbols Used in this Manual Product Specifications 800/1,850 760/2,710 Installation Installation CheckHow to Secure the Drain Pipe Select the Best LocationInstallation Kits Contents Window RequirementsSuggested Tool Requirements Preparation of ChassisCabinet Installation Installation Features OperationControl Locations Function of Controls Cooling Only ModelWG2405RY6 Cooling Only Model with Remote Control and Touch TypeWG2405RY6, WG2405RY6 Disassembly Mechanical PartsFront Grille CabinetAir Handling Parts Cover at the topBlower FanElectrical Parts ShroudMotor CompressorPower Cord CapacitorThermistor Synchronous MotorCapillary Tube Refrigerating CycleEvaporator Disassembly Pulling Vacuum Diagram CN-TH1Wiring Diagram Model WG1805RY6 / WG2405RY6Main P.W.B Assembly Display P.W.B Assembly Components LocationTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electrical Parts Troubleshooting Guide Possible TroubleIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July