Schematic Diagram

Wiring Diagram

• MODEL : WG1805RY6 / WG2405RY6

 

 

 

 

POWER INPUT

 

 

 

 

 

WH(BL)

 

BK(BR)

 

 

 

 

(Ribbed)

 

 

(Plain)

 

 

 

 

 

 

 

GN/YL(GN)

THERMISTOR

 

 

BK

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BL

BL

 

 

 

 

CN-TH1

ASM

MOTOR

RD

RD

 

 

 

 

OR(BR)

OR(BR)

 

 

 

 

 

 

YL

YL

 

 

RY-LO

RY-MID

RY-HI

 

P.W.B

GN/YL

 

 

 

 

CN-SYNC CN-DISP

 

 

 

 

DISPLAY

(GN) CAPACITOR

 

 

 

F

 

 

 

CN-WORK

 

 

 

 

C

 

OR(BR)

SYNC

BK

 

BK

 

BR MOTOR

RD H

 

RD

 

ASM

 

 

 

 

BR

PTC

 

 

 

MAIN P.W.B

 

 

RY-SYNC

 

 

 

 

 

 

 

 

 

 

R

 

BK

 

 

ZNR

 

 

 

RD

 

RY-COMP

 

 

 

 

COMP. S

 

 

 

 

 

 

 

BL

BL

4

3

 

TRANS

 

C

 

 

 

 

 

 

 

 

 

FORMER

 

 

OLP

 

 

 

FUSE

250V/T2A

 

 

 

 

 

 

 

 

 

(115V/T2A)

 

 

3854AR2330P

 

 

 

 

 

 

 

 

 

WIRING DIAGRAM

 

 

 

 

 

 

 

 

23Room Air Conditioner

Image 24
Contents LG Room Air Conditioner Table of Contents Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk or fire or electric shock Dimensions Symbols Used in this ManualOutside Dimensions Product Specifications 800/1,850 760/2,710 Installation Installation CheckHow to Secure the Drain Pipe Select the Best LocationInstallation Kits Contents Window RequirementsSuggested Tool Requirements Preparation of ChassisCabinet Installation Installation Features OperationControl Locations Function of Controls Cooling Only ModelCooling Only Model with Remote Control and Touch Type WG2405RY6, WG2405RY6WG2405RY6 Disassembly Mechanical PartsFront Grille CabinetAir Handling Parts Cover at the topBlower FanElectrical Parts ShroudMotor CompressorPower Cord CapacitorThermistor Synchronous MotorRefrigerating Cycle EvaporatorCapillary Tube Disassembly Pulling Vacuum Diagram CN-TH1Wiring Diagram Model WG1805RY6 / WG2405RY6Main P.W.B Assembly Display P.W.B Assembly Components LocationTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electrical Parts Troubleshooting Guide Possible TroubleIC01M 0V? IC01M DC 5V? Delay? IC01M 0V? Possible Trouble 6 Remote controller does not operate Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide Troubleshooting Guide Exploded View 130910 135515 135500 554031 148000 W48602 Replacement Parts List Replacement Parts List Replacement Parts List Replacement Parts List No A20887A July