Aarrow Fires Gas Stove user manual Installation Instructions Connecting the GAS Supply

Page 13

INSTALLATION INSTRUCTIONS

CONNECTING THE GAS SUPPLY

Once the stove is in place it is then possible to connect the gas supply. The gas supply point is located centrally at the rear (as show in fig.7) and should be connected in accordance with the follow- ing requirements.

Gas Inlet

Rear Of

Valve

Fig. 7

Check that the appliance is suitable for the gas supply; refer to data labels on packaging and/or the stove data label for the gas type.

The gas installation must be in accordance with the current issue of BS6891.Gas supply pressure at the fire should be 20mbar for natural gas & 37mbar for LPG.

The gas supply should be connected with the 12mm fitting and olive supplied with the stove.

A maximum pipe run of 1.5 meters (or 5 feet) should be adhered to. Copper tubing may be used provided a distance of 25mm is maintained between pipe-work and any surface of the stove.

The gas service tap (supplied) should be fitted adja- cent to the fireplace to enable safe removal of the appliance for servicing. After fitting the supply, operate the gas tap (supplied) and check all joints up to the termination of the supply pipe for gas tightness using a soap/water solution and the pres- sure drop method.

To check the pressure to the burner. This must be carried out with all other gas appliances operating at maximum. To check the pressure to the burner it is necessary to ignite the appliance and set to 'high rate'. (See pressure test sequence).

Fig. 8

PRESSURE TEST SEQUENCE

Controls are located at the base of the stove below the ash lip.

Ensure supply is isolated and the valve is in the off position

Step 1. Remove the valve control cover by unscrewing the pozi screw located by knob B and lever the retaining tab to the side of knob A.

Step 2. Locate the outlet pressure tap and unscrew approximately half a turn anti-clockwise with a small flat bladed screw driver. Connect a pressure guage to the outlet pressure tap.

Step 3. Re-connect the supply and light stove. (see lighting and controlling the stove section in the users instructions section of this manual). Turn to high setting. Read pressure guage, setting to be -

20 mbar for Natural Gas or

37 mbar for LPG

Step 4. If any adjustment is required, use the brass screw located between knob B and knob A on the front of the valve, and adjust accordingly to the indication symbol marked upon the valve body.

Step 5. Turn off stove and isolate the supply.

Step 6. Disconnect manometer and re-tighten the outlet pressure tap screw. Do not over tighten.

Step 7 Replace the valve control cover.

Aarrow Sherborne GSL CF

13

Image 13
Contents Sherborne GSL Guarantee ContentsSpare Parts Safety Notices Installation InstructionsGeneral Information Packed details Stove locationUnpacking note Fit for purposeMain Box Statutory Requirements Installation Instructions Important NoticesCertification Installing the Stove Installation Instructions Technical DataMax. Heat Setting Min. Heat SettingStove must not be installed against a combustible wall Installation Instructions Preparation of the StoveStove Location Non-Combustible shelf clearances Installation Instructions Shelf ClearancesInstallation Instructions Flue System Rear Flue Options Closure PlatesTOP Flue Options =See Graph Pressure Test Sequence Installation Instructions Connecting the GAS SupplyFitting and Arranging the Coals Both NG & LPG versions Fitting and Arranging the Logs NG only How to arrange the logsFitting and Arranging the Logs LPG only Installation Instructions For a Manual Stove Without Remote Control Proceed to Installation of Remote Control SystemAssemble Motor Slot Assemble ReceiverHandset Commissioning the Stove Fire TestingAdvise the end user Checklist Servicing Replacement of the Glass Servicing Burner and Valve Assembly RemovalCleaning Outer Surfaces Servicing Annual ServiceSee Safety Notices ref coal set OSD Pilot Fault DiagnosisDate of Visit Company Work Carried Out Signature Annual Service RecordAdditional Notes User Instructions User Instructions Lighting & Controlling the Fire To turn the stove and the pilot off User InstructionsDo not try to force the control, wait the 60 seconds Temperature Display Remote Control Programming the Desired Set Temperature Thermostat and Timer Remote ControlProgramming the Timer Set the display from *C/24 h to *F/12 h and vice versaAutomatic Mode Auto in display for Temperature Control User Instructions User Instructions Important Notices User Instructions Shelf Clearances Part Description Visual Aid Part Number Spare PartsSpare Parts AFGS010 Remoteshb Options & AccessoriesTraceshb AocshbPlease complete the following for you own records GuaranteeAdditional Notes ’ve checked it and it’s O.K