Aarrow Fires Gas Stove user manual Temperature Display Remote Control

Page 34

USER INSTRUCTIONS

NOTE: ONLY FOR STOVES WITH REMOTE CONTROL SYSTEM

TEMPERATURE DISPLAY REMOTE CONTROL

Display

A

Auto

Timer

B

Fig. 21

When the pilot has been lit, the remote transmitter can be used to control the flame height or to turn the main burner on or off.

Aim the remote transmitter at the control valve and press the top button 'A' to increase the input or the bot- tom button 'B' to decrease the input. Short tapping of either button allows incremental change in flame height.

Note! In the event of battery failure the flame height can still be adjusted manually

Caution!

It is recommended to turn the combination control either to the off or pilot position if the appliance is left unattended for long periods (e.g vacation) so that it cannot receive commands from the remote transmitter. Exercise caution when leaving the appliance unattended, and in exceptional cases sound waves from sources other than the transmitter can cause changes in flame height adjustment.

34

Aarrow Sherborne GSL CF

Image 34
Contents Sherborne GSL Guarantee ContentsSpare Parts Safety Notices Installation InstructionsGeneral Information Unpacking note Stove locationPacked details Fit for purposeMain Box Statutory Requirements Installation Instructions Important NoticesCertification Max. Heat Setting Installation Instructions Technical DataInstalling the Stove Min. Heat SettingStove must not be installed against a combustible wall Installation Instructions Preparation of the StoveStove Location Installation Instructions Shelf Clearances Non-Combustible shelf clearancesInstallation Instructions Flue System Rear Flue Options Closure PlatesTOP Flue Options =See Graph Installation Instructions Connecting the GAS Supply Pressure Test SequenceFitting and Arranging the Coals Both NG & LPG versions How to arrange the logs Fitting and Arranging the Logs NG onlyFitting and Arranging the Logs LPG only Installation Instructions Installation of Remote Control System For a Manual Stove Without Remote Control Proceed toAssemble Motor Assemble Receiver SlotHandset Fire Testing Commissioning the StoveAdvise the end user Checklist Servicing Replacement of the Glass Burner and Valve Assembly Removal ServicingCleaning Outer Surfaces Servicing Annual ServiceSee Safety Notices ref coal set Fault Diagnosis OSD PilotAnnual Service Record Date of Visit Company Work Carried Out SignatureAdditional Notes User Instructions User Instructions Lighting & Controlling the Fire To turn the stove and the pilot off User InstructionsDo not try to force the control, wait the 60 seconds Temperature Display Remote Control Programming the Timer Thermostat and Timer Remote ControlProgramming the Desired Set Temperature Set the display from *C/24 h to *F/12 h and vice versaAutomatic Mode Auto in display for Temperature Control User Instructions User Instructions Important Notices User Instructions Shelf Clearances Spare Parts Part Description Visual Aid Part NumberSpare Parts AFGS010 Traceshb Options & AccessoriesRemoteshb AocshbGuarantee Please complete the following for you own recordsAdditional Notes ’ve checked it and it’s O.K