Aarrow Fires Gas Stove user manual OSD Pilot, Fault Diagnosis

Page 28

SERVICING

 

 

 

FAULT DIAGNOSIS

 

 

 

START

 

 

 

 

 

 

 

Does the pilot

Yes

Does the pilot

Yes

Does the main

Yes

Does the stove

Yes

ignite?

stay alight?

burner light?

stay alight?

 

 

 

 

Fire satisfactory

No

 

 

No

 

No

Is the gas supply

No

Is their air in

Yes

Is the main

turned on?

the system?

injector blocked?

 

 

 

 

 

 

No

Purge system

Yes

Turn gas

 

No

 

 

on

 

No

 

Investigate for blocked chimney

 

and adaquate ventilation check

Yes

spillage. If their is no obvious

blockage, seek expert advise.

Clean and replace as necessary

Is the supply

No

 

Is the

pressure

 

thermocouple

 

 

 

correct?

 

 

o.k.?

 

Correct

 

pressure

Yes

Yes

No

Check gas supply and operation of

control valve. Replace if necessary.

 

Replace pilot assembly

OSD

No

Is their a spark at the

 

 

Is pilot flame the correct

Confirm supply

No

 

pressure is correct

electrode?

 

size & playing onto

 

 

 

 

 

 

 

 

thermocouple

Yes

 

 

 

 

 

 

 

Yes

Check for

No

Replace the pilot

spark output

OSD assembly

 

 

 

from control

 

 

 

valve.

 

 

OSD PILOT -

Check if gas is passing from control valve.

Yes

Replace pilot OSD assembly

No Replace pilot

OSD assembly

Replace control valve

Investigate control valve operation and replace if necessary.

Oxygen

Sensing

Device

Pilot

28

Aarrow Sherborne GSL CF

Image 28
Contents Sherborne GSL Guarantee ContentsSpare Parts Safety Notices Installation InstructionsGeneral Information Stove location Packed detailsUnpacking note Fit for purposeMain Box Statutory Requirements Installation Instructions Important NoticesCertification Installation Instructions Technical Data Installing the StoveMax. Heat Setting Min. Heat SettingStove must not be installed against a combustible wall Installation Instructions Preparation of the StoveStove Location Installation Instructions Shelf Clearances Non-Combustible shelf clearancesInstallation Instructions Flue System Rear Flue Options Closure PlatesTOP Flue Options =See Graph Installation Instructions Connecting the GAS Supply Pressure Test SequenceFitting and Arranging the Coals Both NG & LPG versions How to arrange the logs Fitting and Arranging the Logs NG onlyFitting and Arranging the Logs LPG only Installation Instructions Installation of Remote Control System For a Manual Stove Without Remote Control Proceed toAssemble Motor Assemble Receiver SlotHandset Fire Testing Commissioning the StoveAdvise the end user Checklist Servicing Replacement of the Glass Burner and Valve Assembly Removal ServicingCleaning Outer Surfaces Servicing Annual ServiceSee Safety Notices ref coal set Fault Diagnosis OSD PilotAnnual Service Record Date of Visit Company Work Carried Out SignatureAdditional Notes User Instructions User Instructions Lighting & Controlling the Fire To turn the stove and the pilot off User InstructionsDo not try to force the control, wait the 60 seconds Temperature Display Remote Control Thermostat and Timer Remote Control Programming the Desired Set TemperatureProgramming the Timer Set the display from *C/24 h to *F/12 h and vice versaAutomatic Mode Auto in display for Temperature Control User Instructions User Instructions Important Notices User Instructions Shelf Clearances Spare Parts Part Description Visual Aid Part NumberSpare Parts AFGS010 Options & Accessories RemoteshbTraceshb AocshbGuarantee Please complete the following for you own recordsAdditional Notes ’ve checked it and it’s O.K