Aarrow Fires Gas Stove user manual Installation of Remote Control System

Page 18

INSTALLATION INSTRUCTIONS

NOTE: If the optional remote control system has been ordered with the stove and is not fitted please proceed.

FOR A MANUAL STOVE (WITHOUT REMOTE CONTROL) PROCEED TO PAGE 22.

INSTALLATION OF REMOTE CONTROL SYSTEM

Important

A corgi registered gas engineer must carry out the installation of the remote control system

PARTS LIST

1Motor

2Ultrasonic Receiver

3Remote control handset

4Wiring Harness (Multiblock end to reciever, spade connections to motor/micro switch)

5Micro-switch

6AA/LR6 1.5v Batteries (4x) & 9V-6F22 9v Battery (1) Supplied (Not Shown)

4

1

5

2

3

 

 

Fig. 15

 

 

Technical data

 

 

 

Ambient temperature range

Remote and receiver

max. 140deg F / 60deg C

 

Connecting cable

max. 356deg F / 180deg C

Batteries

Quality Alkaline

Handset:

1x9V Block

 

 

Receiver:

4x1.5V AA

18

Aarrow Sherborne GSL CF

Image 18
Contents Sherborne GSL Contents GuaranteeSpare Parts Installation Instructions Safety NoticesGeneral Information Unpacking note Stove locationPacked details Fit for purposeMain Box Installation Instructions Important Notices Statutory RequirementsCertification Max. Heat Setting Installation Instructions Technical DataInstalling the Stove Min. Heat SettingInstallation Instructions Preparation of the Stove Stove must not be installed against a combustible wallStove Location Installation Instructions Shelf Clearances Non-Combustible shelf clearancesInstallation Instructions Flue System Closure Plates Rear Flue OptionsTOP Flue Options =See Graph Installation Instructions Connecting the GAS Supply Pressure Test SequenceFitting and Arranging the Coals Both NG & LPG versions How to arrange the logs Fitting and Arranging the Logs NG onlyFitting and Arranging the Logs LPG only Installation Instructions Installation of Remote Control System For a Manual Stove Without Remote Control Proceed toAssemble Motor Assemble Receiver SlotHandset Fire Testing Commissioning the StoveAdvise the end user Checklist Servicing Replacement of the Glass Burner and Valve Assembly Removal ServicingServicing Annual Service Cleaning Outer SurfacesSee Safety Notices ref coal set Fault Diagnosis OSD PilotAnnual Service Record Date of Visit Company Work Carried Out SignatureAdditional Notes User Instructions User Instructions Lighting & Controlling the Fire User Instructions To turn the stove and the pilot offDo not try to force the control, wait the 60 seconds Temperature Display Remote Control Programming the Timer Thermostat and Timer Remote ControlProgramming the Desired Set Temperature Set the display from *C/24 h to *F/12 h and vice versaAutomatic Mode Auto in display for Temperature Control User Instructions User Instructions Important Notices User Instructions Shelf Clearances Spare Parts Part Description Visual Aid Part NumberSpare Parts AFGS010 Traceshb Options & AccessoriesRemoteshb AocshbGuarantee Please complete the following for you own recordsAdditional Notes ’ve checked it and it’s O.K