Aarrow Fires Gas Stove user manual User Instructions, To turn the stove and the pilot off

Page 33

USER INSTRUCTIONS

Step 3. To turn the stove and the pilot off

completely, turn control knob “A” to the small flame setting, (pilot frame) depress and turn to off position, then release (See Fig. 20e)

BA

Fig. 20e

Important, when control knob “A” is turned to the off position a built-in safety lock is activated which will prevent you from turning the control knob for 60 seconds.

Do not try to force the control, wait the 60 seconds.

NOTE! If the pilot flame is extinguished either intentionally or unintentionally, no attempt to re- light the gas should be until at least 3 minutes has elapsed.

NOTE! During the initial firing, the stove will give off non-toxic fumes when first used. This is perfectly normal and will disappear after the first few hours. It is advised to ventilate the room by opening doors and windows to prevent irritation to to user.

NOTE! The fire doors can be opened during oper- ation, for a greater viewing area to the flame pic- ture, this does not effect the operational perform- ance of the stove.

NOTE! During operation, the metal surface of the stove will be HOT, a operating tool is supplied with the stove and can be used to open the doors if required. See fig. 20f.

CLEANING OUTER SURFACES

It is best cleaned using a soft brush.

Do not allow moisture to remain on the stove while cold or surface rust may occur.

Fig. 20f

Aarrow Sherborne GSL CF

33

Image 33
Contents Sherborne GSL Contents GuaranteeSpare Parts Installation Instructions Safety NoticesGeneral Information Packed details Stove locationUnpacking note Fit for purposeMain Box Installation Instructions Important Notices Statutory RequirementsCertification Installing the Stove Installation Instructions Technical DataMax. Heat Setting Min. Heat SettingInstallation Instructions Preparation of the Stove Stove must not be installed against a combustible wallStove Location Non-Combustible shelf clearances Installation Instructions Shelf ClearancesInstallation Instructions Flue System Closure Plates Rear Flue OptionsTOP Flue Options =See Graph Pressure Test Sequence Installation Instructions Connecting the GAS SupplyFitting and Arranging the Coals Both NG & LPG versions Fitting and Arranging the Logs NG only How to arrange the logsFitting and Arranging the Logs LPG only Installation Instructions For a Manual Stove Without Remote Control Proceed to Installation of Remote Control SystemAssemble Motor Slot Assemble ReceiverHandset Commissioning the Stove Fire TestingAdvise the end user Checklist Servicing Replacement of the Glass Servicing Burner and Valve Assembly RemovalServicing Annual Service Cleaning Outer SurfacesSee Safety Notices ref coal set OSD Pilot Fault DiagnosisDate of Visit Company Work Carried Out Signature Annual Service RecordAdditional Notes User Instructions User Instructions Lighting & Controlling the Fire User Instructions To turn the stove and the pilot offDo not try to force the control, wait the 60 seconds Temperature Display Remote Control Programming the Desired Set Temperature Thermostat and Timer Remote ControlProgramming the Timer Set the display from *C/24 h to *F/12 h and vice versaAutomatic Mode Auto in display for Temperature Control User Instructions User Instructions Important Notices User Instructions Shelf Clearances Part Description Visual Aid Part Number Spare PartsSpare Parts AFGS010 Remoteshb Options & AccessoriesTraceshb AocshbPlease complete the following for you own records GuaranteeAdditional Notes ’ve checked it and it’s O.K