Aarrow Fires Gas Stove Installation Instructions Important Notices, Statutory Requirements

Page 6

INSTALLATION INSTRUCTIONS

IMPORTANT NOTICES

A qualified gas engineer must carry out the installation and servicing of this appliance in accordance with these instructions and in compliance with current Building Regulations.

Such person must be a registered CORGI engineer.

This appliance is designed to run on natural gas (NG) or liquid petrolum gas (LPG) depending up on the model purchased. Warning - Only use the appliance with the specified gas.

The instructions must be read before use of the appliance.

Please note the following;

Sealed components must not be interfered with.

Servicing instructions and part identification numbers are given towards the back of the manual.

Only use genuine Aarrow parts for replacements.

Ventilation, no purpose built ventilation is normally required, normal adventitious room ventilation being suffient.

Coal / log set, see safety notice on page 3 must be observed.

All surfaces except the control knobs are considered to be working surfaces.

Warning: Under no circumstances must the fire be operated if the glass is cracked or broken.

Warning: If it is known or suspected that an operational or ignition fault exists on the appliance, it must not be used until it has been investigated and corrected by a qualified gas engineer.

Warning: THIS GAS APPLIANCE MUST BE SERVICED EVERY TWELVE MONTHS BY A QUALIFIED GAS ENGINEER.

STATUTORY REQUIREMENTS

This product must be installed in accordance with the rules in force.

The current Gas Safety (Installation and Use) Regulations (as amended).

The Building Regulations for England and Wales 2000 ref Approved Document J 2002 edition (issued by the DTLR).

The Building Standards (Scotland) (Consolidation) Regulations.

Detailed recommendations are outlined in the current issue of the following British Standards:- BS5440 parts 1 and 2, BS5871 part 1 and BS6891.

Any Manufacturer's Instructions must not be taken as overriding statutory requirements.

_________________________________________

CERTIFICATION

This appliance is CE certificated for performance and safety. Therefore, it is important that no alteration is made to the appliance.

Any alteration not approved by Arada Ltd will invalidate the guarantee.

6

Aarrow Sherborne GSL CF

Image 6
Contents Sherborne GSL Contents GuaranteeSpare Parts Installation Instructions Safety NoticesGeneral Information Unpacking note Stove locationPacked details Fit for purposeMain Box Installation Instructions Important Notices Statutory RequirementsCertification Max. Heat Setting Installation Instructions Technical DataInstalling the Stove Min. Heat SettingInstallation Instructions Preparation of the Stove Stove must not be installed against a combustible wallStove Location Installation Instructions Shelf Clearances Non-Combustible shelf clearancesInstallation Instructions Flue System Closure Plates Rear Flue OptionsTOP Flue Options =See Graph Installation Instructions Connecting the GAS Supply Pressure Test SequenceFitting and Arranging the Coals Both NG & LPG versions How to arrange the logs Fitting and Arranging the Logs NG onlyFitting and Arranging the Logs LPG only Installation Instructions Installation of Remote Control System For a Manual Stove Without Remote Control Proceed toAssemble Motor Assemble Receiver SlotHandset Fire Testing Commissioning the StoveAdvise the end user Checklist Servicing Replacement of the Glass Burner and Valve Assembly Removal ServicingServicing Annual Service Cleaning Outer SurfacesSee Safety Notices ref coal set Fault Diagnosis OSD PilotAnnual Service Record Date of Visit Company Work Carried Out SignatureAdditional Notes User Instructions User Instructions Lighting & Controlling the Fire User Instructions To turn the stove and the pilot offDo not try to force the control, wait the 60 seconds Temperature Display Remote Control Programming the Timer Thermostat and Timer Remote ControlProgramming the Desired Set Temperature Set the display from *C/24 h to *F/12 h and vice versaAutomatic Mode Auto in display for Temperature Control User Instructions User Instructions Important Notices User Instructions Shelf Clearances Spare Parts Part Description Visual Aid Part NumberSpare Parts AFGS010 Traceshb Options & AccessoriesRemoteshb AocshbGuarantee Please complete the following for you own recordsAdditional Notes ’ve checked it and it’s O.K