Aarrow Fires Gas Stove user manual Servicing Replacement of the Glass

Page 25

SERVICING

REPLACEMENT OF THE GLASS

IMPORTANT

When refitting the glass frame ensure the origi- nal screws are used. Longer screws may foul the coal / log set placement.

Ensure the appliance is cold.

Step 1a For rear flue appliance remove canopy cover plate.

Step 1b For top flue appliance remove infill piece.

Step 2 Remove the fire doors

Open and lift off hinges (held shut by magnet).

Step 3 Disengage locking levers, one per side.

Step 4 Lift the body and canopy off the chassis. Refer to “guide to manual handling” on page 3.

Step 5 Remove dummy fuel retainer (2 screws) If glass is broken, suitable gloves must be worn for protection.

Step 6 Remove glass and glass frame.

Remove any loose glass

Be aware of any glass that will become loose when removing the frame.

•Loosen but do not remove the four screws at the base of the frame.

•Remove all but one of the top centre retaining screws.

•Remove the remaining top screw. The frame and glass will now be loose and can be removed.

•The frame has slots at the base to ease removal. •Remove any remaining loose glass.

Aarrow Sherborne GSL CF

25

Image 25
Contents Sherborne GSL Guarantee ContentsSpare Parts Safety Notices Installation InstructionsGeneral Information Packed details Stove locationUnpacking note Fit for purposeMain Box Statutory Requirements Installation Instructions Important NoticesCertification Installing the Stove Installation Instructions Technical DataMax. Heat Setting Min. Heat SettingStove must not be installed against a combustible wall Installation Instructions Preparation of the StoveStove Location Non-Combustible shelf clearances Installation Instructions Shelf ClearancesInstallation Instructions Flue System Rear Flue Options Closure PlatesTOP Flue Options =See Graph Pressure Test Sequence Installation Instructions Connecting the GAS SupplyFitting and Arranging the Coals Both NG & LPG versions Fitting and Arranging the Logs NG only How to arrange the logsFitting and Arranging the Logs LPG only Installation Instructions For a Manual Stove Without Remote Control Proceed to Installation of Remote Control SystemAssemble Motor Slot Assemble ReceiverHandset Commissioning the Stove Fire TestingAdvise the end user Checklist Servicing Replacement of the Glass Servicing Burner and Valve Assembly RemovalCleaning Outer Surfaces Servicing Annual ServiceSee Safety Notices ref coal set OSD Pilot Fault DiagnosisDate of Visit Company Work Carried Out Signature Annual Service RecordAdditional Notes User Instructions User Instructions Lighting & Controlling the Fire To turn the stove and the pilot off User InstructionsDo not try to force the control, wait the 60 seconds Temperature Display Remote Control Programming the Desired Set Temperature Thermostat and Timer Remote ControlProgramming the Timer Set the display from *C/24 h to *F/12 h and vice versaAutomatic Mode Auto in display for Temperature Control User Instructions User Instructions Important Notices User Instructions Shelf Clearances Part Description Visual Aid Part Number Spare PartsSpare Parts AFGS010 Remoteshb Options & AccessoriesTraceshb AocshbPlease complete the following for you own records GuaranteeAdditional Notes ’ve checked it and it’s O.K