SERVICING
REPLACEMENT OF THE GLASS
IMPORTANT
When refitting the glass frame ensure the origi- nal screws are used. Longer screws may foul the coal / log set placement.
Ensure the appliance is cold.
Step 1a For rear flue appliance remove canopy cover plate.
Step 1b For top flue appliance remove infill piece.
Step 2 Remove the fire doors
Open and lift off hinges (held shut by magnet).
Step 3 Disengage locking levers, one per side.
Step 4 Lift the body and canopy off the chassis. Refer to “guide to manual handling” on page 3.
Step 5 Remove dummy fuel retainer (2 screws) If glass is broken, suitable gloves must be worn for protection.
Step 6 Remove glass and glass frame.
•Remove any loose glass
•Be aware of any glass that will become loose when removing the frame.
•Loosen but do not remove the four screws at the base of the frame.
•Remove all but one of the top centre retaining screws.
•Remove the remaining top screw. The frame and glass will now be loose and can be removed.
•The frame has slots at the base to ease removal. •Remove any remaining loose glass.