Bradley Brand Furniture WF3203, TBD3103 Thermostatic Mixing Valve Troubleshooting

Page 23

Installation

TDB3103, WF3203

Thermostatic Mixing Valve Troubleshooting

NOTE: Before attempting to troubleshoot the valve or disassemble the components, check for the following conditions:

If stop/check valves are used, make sure that they are fully open.

Make sure that the hot and cold inlet pipes are connected properly, and that there are no cross- connections or leaking stop/check valves.

Check the hot water heater output to make sure that it is at least 20° F above the set temperature.

Be sure to close the appropriate shut-off valves prior to disassembly of the valve and reopen the valves after inspection and repair is complete.

Problem: Limited water flow

Cause: Dirt and debris have built up in the valve or strainer.

1.Remove and clean strainer (see Figure 12 or 13 on page 24). If strainer needs to be replaced, order Bradley part no. 173-028.

2.Check the piston for smooth movement.

To check the valve’s piston for free and smooth movement, follow the procedures outlined below:

1.Remove the valve’s cap and thermostat (see Figure 12 on Page 24).

2.Push down on the piston with your finger (the piston should move freely). If the movement is not as it should be, the piston needs to be cleaned. Follow the method outlined below for cleaning the piston and valve body:

Remove the thermostat.

Lift the piston out with a needle-nose pliers and remove the spring.

Any cleaner suitable for brass and stainless steel may be used (if cleaning with suitable cleaner is not sufficient to remove debris, a 400-grit sandpaper may be used to polish and hone the piston and valve body).

Snap spring into piston (will detent) and reassemble into the valve body. Retest the piston.

3.If, after a thorough cleaning, the piston does not move freely, the piston must be replaced. Contact your Bradley representative and ask for Repair Kit (part number S65-259).

Problem: External leaks in the system

Cause: O-rings have been damaged.

Solution: Replace O-rings where necessary. For replacement of the O-rings, contact your Bradley representative and ask for Repair Kit (part number S65-259).

Problem: Improper water temperature or temperature fluctuation

Cause: Thermostat is slowly failing or not working at all.

Solution: Check the thermostat for proper operation.

1.At room temperature (80° F or less) remove cap and thermostat.

2.Place thermostat into container with 115° F water. The pushrod should pop out of the thermostat approximately 1/10".

3.If thermostat pushrod does not pop out, the thermostat must be replaced. Contact your Bradley representative and ask for Repair Kit (part number S65-259).

Cause: Valve temperature is not properly set.

Solution: Adjust the temperature. Using a blade screwdriver, turn the adjustment stem counterclockwise to increase the temperature or clockwise to decrease the temperature.

Bradley Corporation • 215-1332 Rev. T; EN 08-009

3-5-08

23

Image 23 Contents
Commande à infrarouge Installation InstalaciónPre-Installation Information Supplies Required by InstallerTable of Contents Semi-Circular Washfountain Dimensions Semi-Circular Washfountain Dimensions Semi-Circular Washfountain Rough-Ins Rim Height Application AdjustmentType O Drain Rough-In SpecificationsType a Drain Rough-in drain & supplies Bowl/pedestal mounting and assemblySupply Stop Valve connection P-trap installation Installing drain spud in bowlElectrical connections for Adaptive Infrared Adaptive infrared assembly for a drain and O drain unitsShown Installation InstructionsRestraining TOP Cover Bracket Male Connect Female Connect Solenoid Valve Vernatherm Ajustment Instructions Special Situations for Material Cleaning/Maintenance Instructions for TerreonCleaning/Maintenance Instructions for Gel-coated Fiberglass Cleaning and Maintenance Instructions for Stainless Steel Attaching Soap Valve Liquid S09-007S Parts ListSoap Valve Lotion S09-057S Parts List Valve Attaching AssemblyQty Description Parts ListSoap Valve Powdered S09-010A Soap Maintenance Tips Sprayhead Repair Kit Assembly S05-054B Sprayhead Service Suggestions Problem Water splashes over the rim of the bowl Problem Water flow diminishes from the sprayheadIR Actuator Module Assembly Components S50-367Troubleshooting Adaptive IR Solenoid Valve Troubleshooting Solenoid Valve S07-069 closed body Problem External leaks in the system Thermostatic Mixing Valve TroubleshootingProblem Limited water flow Repair Kit S65-259 Matériau Terreon Fournitures requises par l’installateurInformations sur la pré-installation SommaireDe bord Application Ajustement Dimensions du lavabo fontaine semi-circulaireDirectives dimensionnelles ADA Vue de dessus Hauteur de bord Application Ajustement Drain de type O Spécifications de mise en place des tuyauteriesDrain de type a Montage de l’ensemble cuvette et socle Mise en place des tuyauteries de drain et d’alimentationCuvette Installation de l’ergot de drain dans laOpposé DU MUR Connexions électriques pour infrarouge AdaptiveIllustrée Instructions relatives à l’installation suiteCouvercle Console DE Supérieur Retenue Thermostatic Mixing Valve Illustré S45-2233 Instructions de réglage Vernatherm Situations spéciales de matériau Instructions de nettoyage/d’entretien pour TerreonSituations spéciales de matériau Repère Référence Désignation Qté Bouton-poussoir de savon liquide S09-007S NomenclatureBouton-poussoir de lotion savonneuse S09-057S Nomenclature FixationRepère Référence Qté Désignation Bouton-poussoir de savon en poudre S09-010ANomenclature Conseils d’entretien pour le savon Ensemble bec Kit de réparation Diffuseur S05-054B Suggestions pour réparer le bec diffuseurProblème L’eau éclabousse tout autour du bord de la cuvette Actionneur IR Composants de l’ensemble de module I.R. S50-367Dépannage IR Adaptive Guide de dépannage du robinet électromagnétique Robinet électromagnétique S07-069 corps fermé Problème Fuites externes dans le système Dépannage du robinet mélangeur thermostatiqueProblème Débit d’eau limité Kit de réparation S65-259 Robinet mélangeur thermostatique Vernatherm S01-524Material Terreon Suministros requeridos por el instaladorÍndice Información previa a la instalaciónDimensiones de ADA Dimensiones de la fuente de lavado semicircularVista en planta Altura del borde Aplicación Ajuste Figura 1cDesagüe tipo O Desagüe tipo aPalangana/pedestal Desagüe y suministros empotradosMontaje y ensamblaje de Palangana Instalación del embudo de desagüe en la¡NOTA! Vaya hasta el paso E para las unidades sin jabón Se muestra a Instrucciones de instalación continuaciónSoporte DE Cubierta Superior Contención Figura 9b Instrucciones de ajuste de Vernatherm Situaciones especiales del material Instrucciones de limpieza/mantenimiento de TerreonSituaciones especiales del material Válvula para jabón líquido S09-057S Lista de piezas Válvula para jabón líquido S09-007S Lista de piezasArticulo Nº de pieza Cant Descripción Válvula de jabón en polvo S09-010ALista de piezas Consejos para el mantenimiento del jabón Conjunto de boquilla Equipo de Rociadora S05-054B Problema El agua salpica sobre el borde de la palanganaSugerencias de reparaciones de la boquilla rociadora Actuador IR Componentes del conjunto del módulo IR S50-367Localización de fallas del dispositivo IR Adaptive Localización de fallas de la válvula de solenoide Válvula de solenoide S07-069 cuerpo cerrado Problema Fugas externas en el sistema Problema Flujo de agua limitadoEquipo de reparación S65-259 Válvula mezcladora termostática Vernatherm S01-524