h.) Pull out on the blower motor and rotate it 90° so that the exhaust outlet is pointing out the back. Then rotate the blower motor around its exhaust axis 180° so the flat side of the blower motor is pointed up.
NOTE: This is the only way the blower motor will fit properly in the opening.
B
A
C
A. Rotate 90°
B. Rotate 180°
C. Flat side of blower motor
i.) Check that the wiring is properly positioned.
j.) Place the power supply cable and grommet through the center of the outlet hole opening in the mounting panel and reposition the grommet into its mounting notch.
A
A. Grommet/mounting notch
k.) Place the blower mounting panel over the exhaust outlet and mount it onto the hood housing with the 12 mounting screws. Tighten the screws.
l.) Pull the blower motor out through the opening in the blower mounting panel and fasten with the 4 blower mounting screws.
Measure and mark a round vent opening in the soffit using the method shown for venting through the wall. Measure and mark the centerline on the soffit above the range hood area.
A
B
A. Vent cover
B. Centerline
Use the vent cover included with the range hood or other vent cover as a template to outline an opening for the vent. Use a saber saw or keyhole saw to cut a round opening for the vent system.
The range hood can be vented inside through the top of the cabinet.
6¼" (15.9 cm)
Cutout 4¹⁄₈"
(10.5 cm)
Centerline
For
The Recirculation Kit Part Number 4396565 must be used.
5.Install the vent system according to the method needed. Use caulking to seal the exterior wall or roof opening.
6.Run the wiring through the wall or cabinet according to the national Electrical Code and all local codes and ordinances.
Use caulking to seal around wire opening.
10