KitchenAid W10267109C installation instructions Venting Methods, Example vent system 6 15.2 cm

Page 7

Venting Methods

This range hood is factory set for venting through the roof or through the wall.

The vent system needed for installation is not included. A 6" (15.2 cm) round vent system is recommended.

Roof Venting

Wall Venting

B

Example vent system - 6" (15.2 cm)

Wall cap

90˚ elbow

6 ft (1.8 m)

3 ft

(0.93 m)

A

A

B

Maximum Length

= 35 ft (10.7 m)

1

- 90° elbow

=

5 ft (1.5 m)

1

- wall cap

=

0 ft (0 m)

9 ft (2.8 m) straight

=

9 ft (2.8 m)

 

 

System length

= 14 ft (4.3 m)

Non-Vented (recirculating) Installations Through the Soffit/ Cabinet

A. 6" (15.2 cm) vent through

A. 6" (15.2 cm) vent through

the roof

the wall

B. Roof cap

B. Wall cap

Calculate Vent System Length

The recommended vent system is 6" (15.2 cm) round vent with a maximum length of 35 ft (10.7 m). For the best performance, use no more than three 90° elbows.

To calculate the length of the system, add the equivalent feet (meters) for each of the vent pieces used in the system.

Vent Piece

6" (15.2 cm)

45° elbow

2.5 ft

 

(0.8 m)

If it is not possible to vent cooking fumes and vapors to the outside, the range hood can be used in the non-vented (recirculating) version, using charcoal filters. Recirculation Kit Part Number 4396565 is available from the dealer or an authorized parts distributor. Damper installation is not required.

A

A

 

B

B

 

 

C

 

F

D

D

F

 

E

E

90° elbow

5.0 ft

A. Ceiling

D. 6" (15.2 cm) vent

 

(1.5 m)

B. Vent cover

E. Range hood

 

 

C. Soffit

F. Cabinet

 

 

 

 

7

Image 7
Contents W10267109C SLIDE-OUT Vent HoodTable DES Matières Table of ContentsYour safety and the safety of others are very important Range Hood SafetyImportant Safety Instructions ToolsandParts Installation RequirementsLocation Requirements Makeup air Product DimensionsCabinet Dimensions Cold weather installationsExample vent system 6 15.2 cm Venting MethodsCalculate Vent System Length Range Hood Cabinet Cutout Installation InstructionsElectricalRequirements PrepareLocationVenting Outside Through the Wall Venting Outside Through the RoofChange Hood to Optional Rear Exhaust Use caulking to seal around wire opening InstallRange Hood Electrical Connection Vented InstallationsConnecttheVentSystem Optional Gray Vinyl Trim Non-Vented recirculating InstallationsInstall Optional Gray Vinyl Trim Kit Install Front Trim KitFan Control Operating the Fan Range Hood USELight Control Operating the Light Range Hood Care CleaningReplacing the Bulb Wiring Diagram InCanada Assistance or ServiceAccessories IntheU.S.AThis limited warranty does not cover Kitchenaid Ventilation WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA Hotte D’ASPIRATIONImportantes Instructions DE Sécurité Exigences demplacement Exigences D’INSTALLATIONOutilset composants Dimensions du placard Dimensions du produitPour un fonctionnement efficace et silencieux Calcul de la longueur effective du circuit dévacuation Installations pour régions à climat froidAir d’appoint Méthodes d’évacuationOuverture découpée du placard pour la hotte Instructions DinstallationPréparationdelemplacement Spécifications électriquesDécharge à lextérieur, à travers le mur Décharge à lextérieur, à travers le toitÉvacuation par larrière Couvercle du conduit dévacuation Axe central Raccordementélectrique Installationdela hotteGarniture en vinyle gris facultative Installations avec décharge à l’extérieurInstallation sans décharge à l’extérieur recyclage Raccordement du circuit dévacuationEnsembles degarniture avant facultatifs Installation de l’ensemble de garniture avantCommande du ventilateur Fonctionnement du ventilateur Utilisation DE LA HotteNettoyage Entretien DE LA HotteInstallation/remplacement des filtres à charbon RemplacementdelampouleSchémas DE Câblage Accessoires Assistance OU ServiceAuCanada La présente garantie limitée ne couvre pas Garantie DU Système DE Ventilation KitchenaidW10267109C