4.Check that the front panel is parallel with the cabinet front when the screen is pushed in. Slide the screen forward. Tighten the mounting bracket screws so that the range hood is secured to the cabinet.

A

B

A. Mounting bracket screw

B.Flat-blade screwdriver

5.Align the range hood front panel with the cabinet. Slide the screen forward. Locate the 2 screws on each side and turn them counterclockwise to loosen the screws. Adjust the front of the vent vertically, ³⁄₈" (9.5 mm) up or down, or horizontally, ³⁄₄" (19 mm) front to back, until the front is flush with the cabinet. Tighten the screws. If it is necessary to adjust the given dimensions, lower and add or remove the filler strips or redrill mounting holes.

A

B

A. Phillips screwdriver

B. Adjustment screws

Electrical Connection

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Remove terminal box cover.

3.Remove knockout from top of the terminal box and install a UL listed or CSA approved ½" strain relief.

4.Determine the location and mount the terminal box to the inside of the cabinet or wall using the 4 mounting holes in the back of the terminal box. (The mounting screws are not supplied.)

5.Pull house power supply cable through the strain relief into the terminal box.

6.Use UL listed wire connectors and connect black wires (D) together.

7.Use UL listed wire connectors and connect white wires (A) together.

A

 

B

C

E

 

 

D

A. White wires

D. Black wires

B. Green ground screw

E. Wire connectors

C. Ground wire

 

WARNING

Fire Hazard

Electrically ground the blower.

Use copper wire.

Connect ground wire to green ground screw in terminal box.

Failure to do so can result in death, fire, or electrical shock.

8.Connect the green (or bare) ground wire from the home power supply to the green ground screw inside the range hood terminal box. Tighten green ground screw.

Use caulking to seal around wire opening.

9.Tighten strain relief screw.

10.Install terminal box cover.

NOTE: Do not turn on power until installation is complete.

ConnecttheVentSystem

Vented Installations

1.Replace the metal filters. See “Range Hood Care” section.

2.Connect the vent system to the range hood vent opening. Seal the connection with clamps.

3.Reconnect power.

4.Check the operation of the range hood fan and light.

5.Push the range hood screen back in.

12

Image 12
Contents SLIDE-OUT Vent Hood W10267109CTable of Contents Table DES MatièresRange Hood Safety Your safety and the safety of others are very importantImportant Safety Instructions Installation Requirements ToolsandPartsLocation Requirements Product Dimensions Cabinet DimensionsCold weather installations Makeup airVenting Methods Example vent system 6 15.2 cmCalculate Vent System Length Installation Instructions ElectricalRequirementsPrepareLocation Range Hood Cabinet CutoutVenting Outside Through the Roof Venting Outside Through the WallChange Hood to Optional Rear Exhaust Use caulking to seal around wire opening InstallRange Hood Vented Installations Electrical ConnectionConnecttheVentSystem Non-Vented recirculating Installations Install Optional Gray Vinyl Trim KitInstall Front Trim Kit Optional Gray Vinyl TrimRange Hood USE Fan Control Operating the FanLight Control Operating the Light Cleaning Range Hood CareReplacing the Bulb Wiring Diagram Assistance or Service AccessoriesIntheU.S.A InCanadaKitchenaid Ventilation Warranty This limited warranty does not coverSécurité DE LA Hotte D’ASPIRATION Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences D’INSTALLATION Exigences demplacementOutilset composants Dimensions du produit Dimensions du placardPour un fonctionnement efficace et silencieux Installations pour régions à climat froid Air d’appointMéthodes d’évacuation Calcul de la longueur effective du circuit dévacuationInstructions Dinstallation PréparationdelemplacementSpécifications électriques Ouverture découpée du placard pour la hotteDécharge à lextérieur, à travers le toit Décharge à lextérieur, à travers le murÉvacuation par larrière Couvercle du conduit dévacuation Axe central Installationdela hotte RaccordementélectriqueInstallations avec décharge à l’extérieur Installation sans décharge à l’extérieur recyclageRaccordement du circuit dévacuation Garniture en vinyle gris facultativeInstallation de l’ensemble de garniture avant Commande du ventilateur Fonctionnement du ventilateurUtilisation DE LA Hotte Ensembles degarniture avant facultatifsEntretien DE LA Hotte NettoyageRemplacementdelampoule Installation/remplacement des filtres à charbonSchémas DE Câblage Assistance OU Service AccessoiresAuCanada Garantie DU Système DE Ventilation Kitchenaid La présente garantie limitée ne couvre pasW10267109C