KitchenAid W10267109C installation instructions Important Safety Instructions

Page 4

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.

Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.

When cutting or drilling into wall or ceiling; do not damage electrical wiring and other utilities.

Ducted fans must always be vented outdoors. CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

CAUTION: To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into spaces within walls or ceilings, attics or into crawl spaces, or garages.

WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

Always turn hood ON when cooking at high heat or when flambeing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).

Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:a

SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

NEVER PICK UP A FLAMING PAN - you may be burned.

DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

Use an extinguisher ONLY if:

You know you have a class ABC extinguisher, and you already know how to operate it.

The fire is small and contained in the area where it started.

The fire department is being called.

You can fight the fire with your back to an exit.

aBased on "Kitchen Fire Safety Tips" published by NFPA.

READ AND SAVE THESE INSTRUCTIONS

4

Image 4
Contents SLIDE-OUT Vent Hood W10267109CTable of Contents Table DES MatièresRange Hood Safety Your safety and the safety of others are very importantImportant Safety Instructions ToolsandParts Installation RequirementsLocation Requirements Product Dimensions Cabinet DimensionsCold weather installations Makeup airExample vent system 6 15.2 cm Venting MethodsCalculate Vent System Length Installation Instructions ElectricalRequirementsPrepareLocation Range Hood Cabinet CutoutVenting Outside Through the Wall Venting Outside Through the RoofChange Hood to Optional Rear Exhaust Use caulking to seal around wire opening InstallRange Hood Electrical Connection Vented InstallationsConnecttheVentSystem Non-Vented recirculating Installations Install Optional Gray Vinyl Trim KitInstall Front Trim Kit Optional Gray Vinyl TrimFan Control Operating the Fan Range Hood USELight Control Operating the Light Range Hood Care CleaningReplacing the Bulb Wiring Diagram Assistance or Service AccessoriesIntheU.S.A InCanadaKitchenaid Ventilation Warranty This limited warranty does not coverSécurité DE LA Hotte D’ASPIRATION Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Exigences demplacement Exigences D’INSTALLATIONOutilset composants Dimensions du placard Dimensions du produitPour un fonctionnement efficace et silencieux Installations pour régions à climat froid Air d’appointMéthodes d’évacuation Calcul de la longueur effective du circuit dévacuationInstructions Dinstallation PréparationdelemplacementSpécifications électriques Ouverture découpée du placard pour la hotteDécharge à lextérieur, à travers le toit Décharge à lextérieur, à travers le murÉvacuation par larrière Couvercle du conduit dévacuation Axe central Installationdela hotte RaccordementélectriqueInstallations avec décharge à l’extérieur Installation sans décharge à l’extérieur recyclageRaccordement du circuit dévacuation Garniture en vinyle gris facultativeInstallation de l’ensemble de garniture avant Commande du ventilateur Fonctionnement du ventilateurUtilisation DE LA Hotte Ensembles degarniture avant facultatifsEntretien DE LA Hotte NettoyageRemplacementdelampoule Installation/remplacement des filtres à charbonSchémas DE Câblage Accessoires Assistance OU ServiceAuCanada Garantie DU Système DE Ventilation Kitchenaid La présente garantie limitée ne couvre pasW10267109C