Hotpoint 20, 25, 22 Performance Data Sheet, Operating Specifications, Special Notices

Page 19

Performance Data Sheet

SmartWater Filtration System

MWF Cartridge

This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.* (100% safety factors built in for unmetered usage)

Standard No. 42: Aesthetic Effects

Parameter

USEPA

Influent

Influent

Effluent

% Reduction

Min. Required

 

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

Chlorine

2.0 mg/L + 10%

1.96 mg/L

0.06 mg/L

0.11 mg/L

96.77%

94.74%

> 50%

T & O

Particulate**

≥ 10,000 particles/mL

6,400,000 #/mL

58,833 #/mL

150,000 #/mL

99.14%

97.97%

≥ 85%

Standard No. 53: Health Effects

Parameter

USEPA

Influent

Influent

 

 

 

 

 

Effluent

% Reduction

Min. Required

 

 

MCL

Challenge Concentration

Average

 

 

Average

Maximum

Average

Minimum

 

Reduction

Turbidity

0.5 NTU

11 + 1 NTU***

10.5 NTU

 

 

0.14 NTU

0.28 NTU

98.54%

97.20%

 

0.5 NTU

Cysts

≥ 99.95% Reduction

Minimum 50,000 L

118,750 #/L

 

 

 

< 1 #/L

4 #/L

> 99.99%

> 99.99%

 

≥ 99.95%

Asbestos

≥ 99% Reduction

107 to 108 fibers/L; > 10µm

57 MF/L

 

 

0.996 MF/L

< 1 MF/L

99.60%

99.39%

 

≥ 99%

Lead at pH 6.5

0.015 mg/L

0.15 mg/L + 10%

0.1567 mg/L

 

 

< 0.001 mg/L

< 0.001 mg/L

99.36%

99.29%

 

0.010 mg/L

Lead at pH 8.5

0.015 mg/L

0.15 mg/L + 10%

0.1433 mg/L

 

 

< 0.001 mg/L

< 0.001 mg/L

99.30%

99.29%

 

0.010 mg/L

Mercury at pH 6.5

0.002 mg/L

0.006 mg/L + 10%

0.0059 mg/L

 

0.000350 mg/L

0.0007 mg/L

94.70%

87.50%

 

0.002 mg/L

Mercury at pH 8.5

0.002 mg/L

0.006 mg/L + 10%

0.0057 mg/L

 

0.000325 mg/L

0.0006 mg/L

93.20%

89.29%

 

0.002 mg/L

Alachlor

0.002 mg/L

0.04 mg/L + 10%

0.0367 mg/L

 

 

0.00023 mg/L

0.0004 mg/L

99.34%

98.67%

 

0.002 mg/L

Lindane

0.0002 mg/L

0.002 mg/L + 10%

0.0020 mg/L

 

< 0.00002 mg/L

< 0.00002 mg/L

99.00%

98.95%

 

0.0002 mg/L

2,4-D

0.070 mg/L

0.210 mg/L + 10%

0.2033 mg/L

 

 

0.00337 mg/L

0.011000 mg/L

98.32%

94.50%

 

0.070 mg/L

Toxaphene

0.003 mg/L

0.015 mg/L + 10%

0.0160 mg/L

 

 

0.00100 mg/L

0.001000 mg/L

93.44%

91.67%

 

0.003 mg/L

Benzene

0.005 mg/L

0.015 mg/L + 10%

0.0145 mg/L

 

0.000500 mg/L

0.000500 mg/L

96.51%

95.83%

 

0.005 mg/L

Carbofuran

0.040 mg/L

0.080 mg/L + 10%

0.0830 mg/L

 

0.001000 mg/L

0.001000 mg/L

98.78%

98.65%

 

0.04 mg/L

1,4 dichlorobenzene

0.075 mg/L

0.225 mg/L + 10%

0.2283 mg/L

 

0.000500 mg/L

0.000500 mg/L

99.78%

99.77%

 

0.075 mg/L

Atrazine

0.003 mg/L

0.009 mg/L + 10%

0.0087 mg/L

 

 

< 0.0005 mg/L

< 0.0005 mg/L

94.22%

93.33%

 

0.003 mg/L

* Tested using a flow rate of 0.50 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)

 

 

 

 

** Measurement in Particles/ml. Particles used were 0.5-1 microns

 

 

 

 

 

 

 

 

 

 

 

 

*** NTU=Nephelometric Turbidity units

 

 

 

 

 

 

 

 

 

State of California

 

 

Operating Specifications

 

 

 

 

 

 

 

 

 

Department of Health Services

 

 

 

 

 

 

 

 

 

 

 

Water Treatment Device

 

 

￿ Capacity: certified for up to 300 gallons (1135 l); up to six

 

 

 

 

 

 

Certificate Number

 

 

 

months for models without a replacement filter indicator light;

 

 

 

 

 

 

05 - 1698

 

 

 

up to one year for models with a replacement filter indicator light

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿ Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock

 

 

 

 

 

 

Date Issued: February 2, 2005

 

 

￿ Temperature: 33–100ºF (0.6–38ºC)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿ Flow rate: 0.5 gpm (1.9 lpm)

 

 

 

 

 

 

 

Trademark/Model Designation

 

Replacement Elements

General Installation/Operation/Maintenance Requirements

 

 

 

 

MWF

 

 

MWF

 

 

 

 

 

 

Manufacturer: General Electric Company

 

 

 

￿ Flush new cartridge at full flow for 3 minutes to purge out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

trapped air.

 

 

 

 

 

 

 

 

 

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section

￿ Replace cartridge when the indicator light flashes or water

 

 

 

 

116830 of the Health and Safety Code for the following health related contaminants:

 

 

 

 

 

 

 

 

 

 

 

 

flow rate is reduced on non-indicator units.

 

 

 

 

 

 

Microbiological Contaminants and Turbidity

Inorganic/Radiological Contaminants

Special Notices

 

 

 

 

 

 

 

Cysts

 

 

Asbestos

 

 

 

 

 

 

 

 

 

Turbidity

 

 

Lead

 

 

￿ Installation instructions, parts and service availability, and standard

 

 

 

 

 

 

 

Mercury

 

 

 

warranty are included with the product when shipped.

 

 

 

 

 

 

Organic Contaminants

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿ This drinking water system must be maintained according to

 

 

 

 

Alachlor

 

 

 

 

 

 

 

 

 

Atrazine

 

 

 

 

 

 

manufacturer’s instructions, including replacement of filter cartridges.

 

 

Benzene

 

 

 

 

 

￿ Do not use with water that is microbiologically unsafe or of unknown

 

 

 

 

Carbofuran

 

 

 

 

 

 

 

 

Lindane

 

 

 

 

 

 

quality without adequate disinfection before or after the system.

 

 

 

 

Mercury

 

 

 

 

 

 

Systems certified for cyst reduction may be used on disinfected water

 

 

 

 

Toxaphene

 

 

 

 

 

that may contain filterable cysts.

 

 

 

 

 

 

 

1,4-dichlorobenzene

 

 

 

 

 

 

 

 

 

 

 

 

2,4-D

 

 

 

 

 

￿ The contaminants or other substances removed or reduced by this

 

 

 

 

 

 

 

 

 

water treatment system are not necessarily in your water.

 

 

 

 

 

 

 

 

 

 

￿ Check for compliance with the state and local laws and regulations.

 

 

 

 

 

 

 

 

￿ Note that while the testing was performed under standard laboratory

 

 

 

 

 

 

 

 

 

 

 

conditions, actual performance may vary. Systems must be installed and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

operated in accordance with manufacturer’s recommended procedures

 

 

Rated Service Capacity: 300 gal

 

Rated Service Flow:

0.5 gpm

 

and guidelines.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for

 

 

 

 

 

 

 

 

 

 

 

 

 

Conditions of Certification:

 

 

 

 

 

 

 

 

 

 

 

 

 

cyst reduction may be used on disinfected waters that may contain filterable cysts.

 

 

 

System Tested and Certified by NSF International against

 

 

 

 

 

 

 

 

 

 

 

 

 

ANSI/NSF Standard 42 & 53 for the reduction of:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Standard No. 42: Aesthetic Effects

 

Standard No. 53: Health Effects

 

 

 

 

 

 

 

 

 

 

 

Chemical Unit

 

 

Chemical Reduction Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

Chlorine Taste and Odor

 

Alachlor and Atrazine Reduction

 

 

 

 

 

 

 

 

 

 

 

Mechanical Filtration Unit

 

Benzene and Carbofuran Reduction

 

 

 

 

 

 

 

 

 

 

 

 

1,4 dichlorobenzene and 2,4-D Reduction

 

 

NSF®

 

 

 

 

 

 

Particulate Reduction, Class I

 

 

 

 

 

 

 

 

 

 

Lead and Lindane Reduction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mercury and Toxaphene Reduction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mechanical Filtration Unit

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

Turbidity Reduction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cyst and Asbestos Reduction

 

 

Manufactured for: General Electric Company, Louisville, KY 40225

 

 

 

 

 

 

EPA EST. No. 070595-MN-001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 19
Contents Model # Serial # RefrigeratorsBefore You Throw Away Your Old Refrigerator or Freezer Consumer SupportRefrigerants Instructions Installation Instructions Troubleshooting Tips Consumer SupportFreezer Pan Freezer Shelves Rearranging the ShelvesTo remove Lift Refrigerator ShelvesCrisper Removal Adjustable Humidity Crispers and Snack Pan on some modelsTips Consumer Support Spillproof Shelves on some modelsTo Change Temperature Control Setting with Touch Pads Startup Steps for Proper Temperature ControlAbout the controls on the refrigerator About the automatic icemaker About the water filter cartridge. On some modelsTips To Use the Dispenser Troubleshooting Tips Installation InstructionsIcemaker Accessory Kit About the ice and water dispenser. On some modelsCare and cleaning of the refrigerator Door Alignment Refrigerator LocationRollers ClearancesWhat YOU will Need Before YOU BeginConnect the Tubing to Valve Shut OFF Main Water Supply Drill the Hole for the ValveFasten the Shutoff Valve Route the TubingPlug in the Refrigerator Turn the Water on AT the Shutoff ValveStart the Icemaker Normal operating sounds Before you call for service…Safety Dispenser Water in first glass isWater dispenser does Water spurting fromCustomer Warranty What Is Not Covered Operating Instructions Safety InstructionsWe Will Replace Special Notices Performance Data SheetOperating Specifications General Installation/Operation/Maintenance RequirementsConsumer Product Ownership Registration For customers in Canada For customers in the United StatesGeneral Electric Company La clientèle FonctionnementRéfrigérants Service à la clientèle Conseils de dépannage InstallationRéarrangement des clayettes Installation des accessoiresService à la clientèle Mesures de sécuritéBac à viande transformable sur certains modèles Installation De dépannageClayette coulissante anti-déversement sur certains modèles Clayettes anti-débordements sur certains modèlesLes commandes Mesures de La cartouche du filtre à eau. sur certains modèlesMachine à glaçons automatique SécuritéVerrouillage du distributeur Le distributeur d’eau et de glaçons. sur certains modèlesNécessaire de machine à glaçons Pour utiliser le distributeurEntretien et nettoyage du réfrigérateur Alignement DES Portes Emplacement DU RéfrigérateurRoulettes DE Nivellement Alimentation D’EAU À LA MachineCE Dont Vous Aurez Besoin Avant DE CommencerAcheminez LE Tuyau Percez UN Trou Pour LE RobinetBranchez LE Tuyau AU Robinet Fixez LE Robinet D’ARRÊTBranchez Votre Réfrigérateur Fermez L’EAU AU Niveau DU Robinet D’ARRÊTMarche Entendez-vous ce que j’entends ? Ces bruits sont normaux Mesures de sécurité Fonctionnement InstallationBruits de fonctionnement normaux Avant d’appeler un réparateur…Installation Service à la clientèle Conseils de dépannage De sécurité Mesures’ouverture des portes Consultez Remplacement des ampoulesDe la condensation Par temps humideAgraphez votre reçu ici Garantie DU ClientCarbofurane Feuillet de données relatives à la performanceService de réparations Service à la clientèleProlongation de garantie Refrigerantes Operación InstalaciónServicio al Antes de deshacerse de su viejo refrigerador o congeladorOperación Como Conectar LA ElectricidadEntrepaños del refrigerador Cómo instalar los accesoriosSeguridad Reubicación de los entrepañosContenedor convertible para carnes en algunos modelos SolucionarEntrepaños a prueba de derrames en algunos modelos Como sacar la gaveta preservadora de alimentosUn ajuste Instalación Servicio al consumidor Solucionar problemasLos controles del refrigerador Pasos de inicio para un correcto control de la temperaturaEl dispositivo automático para hacer hielo El cartucho del filtro de agua. en algunos modelosServicio al consumidor Solucionar problemasAtrás del refrigerador Cuidado y limpieza del refrigeradorLimpiar el exterior Limpiar el interiorPosición vertical durante la mudanza Preparación para vacacionesEn caso de mudanza Reemplazo de bombillasEspacios Libres Ubicación DEL RefrigeradorRodillos Alineado DE LAS Puertas Instrucciones para la instalaciónQUÉ Necesita Antes DE IniciarBien Instale LA Válvula DE CierreLave LA Tubería Dirija LA TuberíaConecte EL Refrigerador Conecte LA Tubería AL RefrigeradorInicie LA Máquina DE Hielos Dispositivo para hacer hielo en algunos modelos Sonidos normales de la operaciónAntes de solicitar un servicio… Seguridad Operación InstalaciónCongelador demasiado Vea Los controlesCompartimiento de Alimentos frescos oNo funciona El agua tiene unSabor/olor malo En algunos modelosDe murmullo Aire caliente a la baseCrushed ICE hielo picado Modelos Frecuente sonidoUn año Seguridad OperaciónReemplazaremos Lo que no cubriremosPlomo a pH 8,5 Factores de 100% incorporados para la utilización no medidaPiezas y accesorios Servicio al consumidor Página Web de HotpointSolicite una reparación Garantías ampliadasConsumer Support Hotpoint Website Schedule Service
Related manuals
Manual 28 pages 33.72 Kb