Frymaster BIGLA30 After adding Cleaning Solution, Start Deep Clean, Clean fry baskets, Clean Done

Page 13

Deep Clean Mode JIB System (continued)

14After adding Cleaning Solution

Computer displays

SOLUTION ADDED alternating with YES.

Press the 1 key.

15Start Deep Clean

Computer displays DEEP CLEAN alternating with a countdown timer for one hour. The solution will reach a temperature of 195°F (91°C). The solution should be at a soft, rolling simmer. Complete steps 15 through 18 while the timer is running.

The solution should never come to a rolling boil, or it may boil over. If unit starts to boil over cancel deep clean by pressing and holding the 2x button for three seconds.

Never leave the fryer unattended during deep clean.

16Clean fry baskets.

Place the fry baskets into the cleaning solution. Have another crew person remove them when clean and take them to the three- compartment-sink. Rinse and dry them thoroughly.

Do not place any aluminum parts in the boiling solution. The solid metal basket hangers are made of aluminum.

17Clean basket support rack.

Use the goofer stick to remove the basket support rack from the vat. Have another crew person take the rack to the three- compartment-sink, and rinse it thoroughly in hot water. Dry thoroughly.

The basket support rack is very hot.

18Scrub inside of vat.

Scrub the side, front, and back walls of the vat with a heat-resistant pot brush to remove any remaining deposits.

19Clean Done

After one hour, the computer displays CLEAN DONE and

sounds an alarm. Press 1 to silence alarm.

20Drain solution from vat.

Follow Kay Chemical Deep Cleaning Procedure to remove solution.

The computer displays IS SOLUTION REMOVED? alternating with YES. Once the solution is removed press 1 button.

The solution will be very hot. Avoid splashing.

Frymaster BIELA14 and BIGLA30 – LOV Fryer

Quarterly

FR 3 Q1

©McDonald’s Corporation · Planned Maintenance Manual · Revised May 2011

Page 3 of 4

Image 13
Contents Weekly maintenance tasks Daily maintenance tasksBi-weekly maintenance task Monthly maintenance taskFR 3 D1 Remove and empty grease trough and cup FR 3 W1Shut off and disconnect gas Prepare fryer for cleaning Clean area behind fryersClean fryer filters Disconnect fryer from electricityAsk manager to inspect Clean area behind fryerWash fryer legs and casters Mop floor around fryerClean area behind other fryers Reinstall fryer filters and grease troughTurn on gas supply FR 3 B1 Procedure Calibrate pyrometerTurn on fryer and heat oil Check oil levelCalibrate fryer Check most recent recovery time ProcedureTurn fryer off Adjust fryer, if necessary Calibrate fryer recovery time Check recovery time again Recalibrate all remaining fryersEnter Deep Clean mode Prepare for Deep Clean Remove filter pan Turn fryer offFR 3 Q1 Position MsduDeep Clean Mode JIB System Start Deep Clean After adding Cleaning SolutionClean fry baskets Clean basket support rackDraining Dry Vat, Clean and Dry PanRinse vat with water Rinse CompleteFR 3 Q2 Prepare for Deep Clean Enter Deep Clean mode Turn fryer offVat empty Deep Clean Mode Bulk SystemOpen dispose valve DisposingInsert filter pan Close dispose valveComputer displays Rinse COMPLETE? alternating with YES Filling 30 Vat, Pan DryFR 3 Q3 Verify high-limit controls Clean pickup tubes Procedure Prepare fryer for procedureReinstall filter pan FR 3 Q4FR 3 A1-T Annual Inspection electric fryers only Check regulated gas pressure FR 3 A2-TCheck combustion Annual Inspection gas fryers only Adjust combustion air blower, if necessary
Related manuals
Manual 88 pages 5.79 Kb Manual 86 pages 17.38 Kb Manual 86 pages 43.72 Kb Manual 96 pages 23.21 Kb