| Annual Inspection (gas fryers only) |
|
|
| Annually |
|
|
| FR 3 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
| Why | Frymaster recommends that a Factory Authorized Service Technician inspect this appliance at least | |||||||||
|
| annually. This will help ensure the equipment is in safe working order and operating at peak per- | |||||||||
| Time required | formance. |
|
|
|
|
|
|
|
| |
| 1.5 hours to complete |
|
|
|
|
|
|
|
| ||
| Time of day | The inspection should be scheduled by the store to ensure business is not interrupted and to give |
the servicer adequate access to the equipment.
Hazard icons
Tools and supplies
Tools supplied by technician
Frymaster Fryer Model BIGLA30 – LOV
Procedure
QUALIFIED TECHNICIANS ONLY
1Cabinet inspection
Inspect the cabinet, inside and out, front and rear, for excessive oil buildup.
2Check regulated gas pressure.
Contact the local gas company or a service agency to check the gas pressure out of the fryer’s gas regulator.
For natural gas, the pressure must be 3.0 in. W.C.
(76 mm W.C.) For propane gas, the pressure must be 8.25 in. W.C. (210 mm W.C.)
If the pressure does not meet these standards, ask the service agency or gas company to adjust the pressure to meet the standard.
3Probe check
Verify that the temperature and
4Clean and Replace gas valve vent tube.
Clean and replace the gas valve vent tube. Follow the cleaning procedure in the service manual.
5Clean combustion air blower.
Clean the combustion air blowers. Follow the cleaning procedure in the service manual.
6Check fryer recovery time.
Choose a vat on the fryer. Check the fryer’s most re- cent recovery time for that vat, using the procedure in FR3 M1. The most recent recovery time should be less than 2:25 (two minutes,
If the fryer’s recovery time is less than 2:25 (two mi- nutes,
7Check combustion.
If the fryer’s recovery time is less than 2:25 (two mi- nutes,
Connect the multimeter in series with the white flame sensor wire on the igniter. Allow the burner to operate for at least one minute after the melt cycle is com- pleted. After 1 minute, the reading on the multimeter should between 2.5 and 3.5 microamps. Any other reading is not acceptable.
After 90 seconds of continuous operation, check the color of the burner. The burner should glow bright
QUALIFIED TECHNICIANS ONLY Annually FR 3
©McDonald’s Corporation · Planned Maintenance Manual · Revised June 2009 | Page 1 of 1 |