Frymaster BIGLA30 warranty Filter Stats Mode, Full VAT Configuration, Split VAT Configuration

Page 59

2. Press the t and ubuttons to scroll between:

FULL VAT CONFIGURATION

 

a. filter stats

See pg. 4-35

b. review usage

See pg. 4-36

c. last load

See pg. 4-37

SPLIT VAT CONFIGURATION

 

a. filter stats

See pg. 4-35

b. review usage

See pg. 4-36

c. last load L

See pg. 4-37

d. last load R

See pg. 4-37

NOTE:

Use the 3and 4 buttons to move between days within the selections.

Press the t and u buttons to move to other menu items.

3. With the desired selection displayed, press the (1 yes) button to select chosen menu item.

4.14.1 FILTER STATS MODE

The filter stats mode displays vat filtration counts and skipped filters by day and the average number of cook cycles per filter prompt.

1.Perform steps 1-3 on pages 4-34 through 4-35. The computer displays filter STATS.

2. With the desired selection displayed, press the (1 yes) button.

The computer displays current day on the left side and current date on the right side.

3.Use the 3and 4 buttons to scroll records; starting at the current day and going back one week.

4.Press the t and ubuttons to scroll between:

FULL VAT CONFIGURATION

a. DAY (TUE), DATE (07/03/07) – Current day and date. b. fIltErEd # day, – Number of times vat filtered and day.

c. flt bpsd # day, – Number of times filter was bypassed and day. d. flt avg day, – Average number of cook cycles per filter and day.

4-35

Image 59
Contents Manufactured Canada Page LOV GAS Warranty Statement Parts Return General Safety InformationEuropean Community CE Specific Information Installation, Operating, and Service PersonnelComputer Information for the M3000 Computers Qualified AND/OR Authorized Operating Personnel Qualified Installation PersonnelQualified Service Personnel Retain and Store this Manual in a Safe Place for Future USE Clearance and Ventilation General Installation RequirementsElectrical Grounding Requirements National Code RequirementsCaster Installation Non-CE Standard For Incoming Gas Pressures Gas Connection Pipe Sizes CE Standard Gas Vat Converting to Another Gas TypeCE GAS Conversion Instructions After Fryers are Positioned at the Frying Station BIGLA30 Series GEN II LOV GAS Fryer Operating Instructions Typical Configuration BIGLA330 ShownPage Lighting the Fryer Press the computer ON/OFF switch to the OFF positionOperation ShutdownChanging the JIB Low Oil Volume Automatic RefillInstall the JIB Prepare the System for UseFront of the fryer off see Figure M3000 General Information FR FriesBasic Operation Cooking with Multi-Product Display Cooking with Dedicated Display Changing from Breakfast Setup to Lunch Changing from Lunch Setup to Breakfast Cook Channel and Selection Buttons Filter, Temperature and Info ButtonsM3000 Button Description and Functions Navigation ButtonsDraining, Refilling, and Disposing of Oil M3000 Menu Summary Tree1234 Fryer Setup Mode Programming24hR Full 10 M3000 Common TasksEscape Menu Items Prod Adding New Product Items to the Menu Product SelectionSelection ProductCook ID Disable To Level 1 program changing to the Product selection Storing Menu Items in Product ButtonsProduct selection prompt Disposal for Non-Bulk Oil Systems Draining and Refilling Vats, and Disposing of OilRefilling JIB Oil Systems Draining and Disposing Oil using Bulk Oil SystemsPage Refilling the Vat from Bulk Oil Systems after Disposal Accessing the Filter MenuDrain to Pan Yes no Fill Vat from Drain PanFill Vat from Bulk Pan to Waste Programming Level OneAIF Clock Selection display Deep Clean Mode BOIL-OUTEMPTY? and Yes no PANPage HIGH-LIMIT Test Mode Comp Programming Level TwoLevel 2 Program Product Comp ModePassword Setup Mode LOG Mode Alert Tone Mode Filter After Filter Time Info ModeSplit VAT Configuration Filter Stats ModeFull VAT Configuration DAY wed, Date 03/20/07 Current day and date Review Usage Mode4321 Last Load ModeFull / Split VAT Configuration Page Introduction BIGLA30 Series GEN II LOV GAS Fryer Filtration InstructionsDo not USE Filter Powder with the PAD Auto Demand Filtration DRAINING, Washing and Filling during the processPage Clogged Drain Error FIXED? YES no is displayed Filter Error FlowchartSystem Error Normal Operation ResumesClogged Drain or Oil Sensor Fail Flowchart Filter Busy Page Page Clean Fryer Cabinet Inside and Out Daily Fryer Preventive Maintenance Checks and ServiceDaily Checks and Service Inspect Fryer and Accessories for DamageClean Filter Pan, Detachable Parts and Accessories Weekly Checks and Service 6.3.1 Clean Behind FryersCleaning the Frypot Quarterly Deep Clean Boiling Out the FrypotCheck M3000 Computer Set Point Accuracy BI-WEEKLY Checks and ServiceQuarterly Checks and Service Clean Combustion Air Blower AssemblyLeft Viewing PortRight Port is Behind Motor Fryer Clean Oil Level SensorReplace the O-RINGS Annual/Periodic System InspectionBuilt-In Filtration System BIGLA30 Series GEN II LOV GAS Fryer Operator Troubleshooting Change Filter Service Auto Top Off Problems Probable Causes Corrective Action Explanation ProblemError Drain Valve not Closed Used oil to a JIB Bulk Oil SystemsMelter ON/OFF switch Reset oil reservoir system Service Hotline