Frymaster BIGLA30 warranty Clogged Drain Error

Page 67

*NOTE: If the filter pad change time has expired, normally every 25 hours, the CHANGE FILTER PAD? message repeats every 15 minutes instead of every four minutes.

6.Remove the pan. The computer display changes to CHANGE PAD. Change the filter pad and ensure the filter pan has been pulled forward, out of the cabinet for at least 30 seconds. Once the pan has been out for 30 seconds the computer displays OFF. Ensure the pan is dry and assembled correctly. Push the filter pan back into the fryer. Ensure “A” is displayed on the MIB board.

7.Switch the computer on. The computer displays low temp until the fryer reaches setpoint.

8.If a filtration error occurs six consecutive times, the return valve closes and the computer displays SERVICE REQUIRED alternating with YES and an alarm.

9.Press 9 (1 yes) to silence alarm and continue.

The computer displays SYSTEM ERROR and the error message for 15 seconds changing to SYSTEM ERROR FIXED alternating with YES NO.

10.Press 8 (2 NO) to continue cooking. Call your ASA to repair and reset the fryer. The error will be re-displayed every 15 minutes until the issue is repaired. Auto filtration and auto top off is disabled until the fryer is reset.

5.4.2Clogged Drain Error

The clogged drain error occurs during auto filtration when the oil level sensor detects that oil has not completely drained from the frypot. This may be due to a clogged drain or an oil sensor failure. Follow the instructions on the computer display using the chart on page 5-7 to clear the error.

When this occurs the computer displays CLEAR DRAIN for 15 seconds changing to IS DRAIN CLEAR? alternating with YES.

1.Clear debris from the drain using the fryer’s friend and press the 9 (1 yes) button to continue.

2.The computer displays DRAINING. Once the oil level sensor detects the oil has drained, normal auto filtration operation resumes.

5-5

Image 67
Contents Manufactured Canada Page LOV GAS Warranty Statement Parts Return General Safety InformationComputer Information for the M3000 Computers Installation, Operating, and Service PersonnelEuropean Community CE Specific Information Qualified Service Personnel Qualified Installation PersonnelQualified AND/OR Authorized Operating Personnel Retain and Store this Manual in a Safe Place for Future USE Clearance and Ventilation General Installation RequirementsElectrical Grounding Requirements National Code RequirementsCaster Installation Non-CE Standard For Incoming Gas Pressures Gas Connection Pipe Sizes CE Standard Gas Vat Converting to Another Gas TypeCE GAS Conversion Instructions After Fryers are Positioned at the Frying Station BIGLA30 Series GEN II LOV GAS Fryer Operating Instructions Typical Configuration BIGLA330 ShownPage Lighting the Fryer Press the computer ON/OFF switch to the OFF positionOperation ShutdownChanging the JIB Low Oil Volume Automatic RefillInstall the JIB Prepare the System for UseFront of the fryer off see Figure M3000 General Information FR FriesBasic Operation Cooking with Multi-Product Display Cooking with Dedicated Display Changing from Breakfast Setup to Lunch Changing from Lunch Setup to Breakfast Cook Channel and Selection Buttons Filter, Temperature and Info ButtonsM3000 Button Description and Functions Navigation ButtonsDraining, Refilling, and Disposing of Oil M3000 Menu Summary Tree1234 Fryer Setup Mode Programming24hR Escape Menu Items 10 M3000 Common TasksFull Prod Adding New Product Items to the Menu Product SelectionSelection ProductCook ID Disable Product selection prompt Storing Menu Items in Product ButtonsTo Level 1 program changing to the Product selection Disposal for Non-Bulk Oil Systems Draining and Refilling Vats, and Disposing of OilRefilling JIB Oil Systems Draining and Disposing Oil using Bulk Oil SystemsPage Refilling the Vat from Bulk Oil Systems after Disposal Accessing the Filter MenuDrain to Pan Yes no Fill Vat from Drain PanFill Vat from Bulk Pan to Waste Programming Level OneAIF Clock Selection display Deep Clean Mode BOIL-OUTEMPTY? and Yes no PANPage HIGH-LIMIT Test Mode Comp Programming Level TwoLevel 2 Program Product Comp ModePassword Setup Mode LOG ModeAlert Tone Mode Filter After Filter Time Info ModeFull VAT Configuration Filter Stats ModeSplit VAT Configuration DAY wed, Date 03/20/07 Current day and date Review Usage ModeFull / Split VAT Configuration Last Load Mode4321 Page Introduction BIGLA30 Series GEN II LOV GAS Fryer Filtration Instructions Do not USE Filter Powder with the PAD Auto Demand Filtration DRAINING, Washing and Filling during the processPage Clogged Drain Error FIXED? YES no is displayed Filter Error FlowchartSystem Error Normal Operation ResumesClogged Drain or Oil Sensor Fail Flowchart Filter Busy Page Page Clean Fryer Cabinet Inside and Out Daily Fryer Preventive Maintenance Checks and ServiceDaily Checks and Service Inspect Fryer and Accessories for DamageClean Filter Pan, Detachable Parts and Accessories Weekly Checks and Service 6.3.1 Clean Behind FryersCleaning the Frypot Quarterly Deep Clean Boiling Out the FrypotCheck M3000 Computer Set Point Accuracy BI-WEEKLY Checks and ServiceQuarterly Checks and Service Clean Combustion Air Blower AssemblyLeft Viewing PortRight Port is Behind Motor Fryer Clean Oil Level SensorReplace the O-RINGS Annual/Periodic System InspectionBuilt-In Filtration System BIGLA30 Series GEN II LOV GAS Fryer Operator Troubleshooting Change Filter Service Auto Top Off Problems Probable Causes Corrective Action Explanation ProblemError Drain Valve not Closed Used oil to a JIB Bulk Oil SystemsMelter ON/OFF switch Reset oil reservoir system Service Hotline