Frymaster BIGLA30 warranty BI-WEEKLY Checks and Service, Check M3000 Computer Set Point Accuracy

Page 75
Blower
assembly
mounting nuts

Wipe the filter pan and all detachable parts and accessories with a clean dry cloth. Use a cloth dampened with a solution of McDonald’s All Purpose Concentrate to remove accumulated carbonized oil. Rinse and thoroughly dry each part. DO NOT use steel wool or abrasive pads to clean these parts. The scratches that result from such scrubbing make subsequent cleanings more difficult.

6.4BI-WEEKLY CHECKS AND SERVICE

6.4.1 Check M3000 Computer Set Point Accuracy

1.Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the fryer temperature- sensing probe.

2.When the computer display shows a series of dashes “----” or a product name (indicating that the frypot

contents are within the cooking range), press the switch once to display the temperature of the oil as sensed by the temperature probe.

3.Press the switch twice to display the set point.

4.Note the temperature on the thermometer or pyrometer. Actual temperature and pyrometer readings should be within ± 5ºF (3ºC) of each other. If not, contact a Factory Authorized Service Agency for assistance.

6.5QUARTERLY CHECKS AND SERVICE

6.5.1 Clean Combustion Air Blower Assembly

1. Disconnect the blower wiring harness and remove the four blower mounting nuts. (See Figure 1 on below)

Wiring connection

Figure 1

2.Remove the three fasteners that secure the blower motor assembly to the blower housing, and separate the two components. (See Figure 2)

Remove these fasteners.

Figure 2

6-3

Image 75
Contents Manufactured Canada Page LOV GAS Warranty Statement Parts Return General Safety InformationInstallation, Operating, and Service Personnel Computer Information for the M3000 ComputersEuropean Community CE Specific Information Qualified Installation Personnel Qualified Service PersonnelQualified AND/OR Authorized Operating Personnel Retain and Store this Manual in a Safe Place for Future USE Clearance and Ventilation General Installation RequirementsElectrical Grounding Requirements National Code RequirementsCaster Installation Non-CE Standard For Incoming Gas Pressures Gas Connection Pipe Sizes CE Standard Gas Vat Converting to Another Gas TypeCE GAS Conversion Instructions After Fryers are Positioned at the Frying Station BIGLA30 Series GEN II LOV GAS Fryer Operating Instructions Typical Configuration BIGLA330 ShownPage Lighting the Fryer Press the computer ON/OFF switch to the OFF positionOperation ShutdownChanging the JIB Low Oil Volume Automatic RefillInstall the JIB Prepare the System for UseFront of the fryer off see Figure M3000 General Information FR FriesBasic Operation Cooking with Multi-Product Display Cooking with Dedicated Display Changing from Breakfast Setup to Lunch Changing from Lunch Setup to Breakfast Cook Channel and Selection Buttons Filter, Temperature and Info ButtonsM3000 Button Description and Functions Navigation ButtonsDraining, Refilling, and Disposing of Oil M3000 Menu Summary Tree1234 Fryer Setup Mode Programming24hR 10 M3000 Common Tasks Escape Menu ItemsFull Prod Adding New Product Items to the Menu Product SelectionSelection ProductCook ID Disable Storing Menu Items in Product Buttons Product selection promptTo Level 1 program changing to the Product selection Disposal for Non-Bulk Oil Systems Draining and Refilling Vats, and Disposing of OilRefilling JIB Oil Systems Draining and Disposing Oil using Bulk Oil SystemsPage Refilling the Vat from Bulk Oil Systems after Disposal Accessing the Filter MenuDrain to Pan Yes no Fill Vat from Drain PanFill Vat from Bulk Pan to Waste Programming Level OneAIF Clock Selection display Deep Clean Mode BOIL-OUTEMPTY? and Yes no PANPage HIGH-LIMIT Test Mode Comp Programming Level TwoLevel 2 Program Product Comp ModePassword Setup Mode LOG ModeAlert Tone Mode Filter After Filter Time Info ModeFilter Stats Mode Full VAT ConfigurationSplit VAT Configuration DAY wed, Date 03/20/07 Current day and date Review Usage ModeLast Load Mode Full / Split VAT Configuration4321 Page Introduction BIGLA30 Series GEN II LOV GAS Fryer Filtration InstructionsDo not USE Filter Powder with the PAD Auto Demand Filtration DRAINING, Washing and Filling during the processPage Clogged Drain Error FIXED? YES no is displayed Filter Error FlowchartSystem Error Normal Operation ResumesClogged Drain or Oil Sensor Fail Flowchart Filter Busy Page Page Clean Fryer Cabinet Inside and Out Daily Fryer Preventive Maintenance Checks and ServiceDaily Checks and Service Inspect Fryer and Accessories for DamageClean Filter Pan, Detachable Parts and Accessories Weekly Checks and Service 6.3.1 Clean Behind FryersCleaning the Frypot Quarterly Deep Clean Boiling Out the FrypotCheck M3000 Computer Set Point Accuracy BI-WEEKLY Checks and ServiceQuarterly Checks and Service Clean Combustion Air Blower AssemblyLeft Viewing PortRight Port is Behind Motor Fryer Clean Oil Level SensorReplace the O-RINGS Annual/Periodic System InspectionBuilt-In Filtration System BIGLA30 Series GEN II LOV GAS Fryer Operator Troubleshooting Change Filter Service Auto Top Off Problems Probable Causes Corrective Action Explanation ProblemError Drain Valve not Closed Used oil to a JIB Bulk Oil SystemsMelter ON/OFF switch Reset oil reservoir system Service Hotline