E11 | ERROR DRAIN VALVE NOT CLOSED | Drain valve was trying to close and confirmation |
|
| is missing |
E12 | ERROR RETURN VALVE NOT OPEN | Return valve was trying to open and confirmation |
|
| is missing |
E13 | ERROR RETURN VALVE NOT CLOSED | Return valve was trying to close and confirmation |
|
| is missing |
E14 | ERROR AIF BOARD | MIB detects AIF missing; AIF board failure |
E15 | ERROR MIB BOARD | Cooking computer detects MIB connections lost; |
|
| MIB board failure |
E16 | ERROR AIF PROBE | AIF RTD reading out of range |
E17 | ERROR ATO PROBE | ATO RTD reading out of range |
E18 | Not used |
|
E19 | M3000 CAN TX FULL | Connection between computers lost |
E20 | INVALID CODE LOCATION | SD card removed during update |
E21 | FILTER PAD PROCEDURE ERROR | 25 hour timer has expired or dirty filter logic has |
| (Change Filter Pad) | activated |
E22 | OIL IN PAN ERROR | The MIB has reset the oil in pan flag. |
E23 | CLOGGED DRAIN (Gas) | Vat did not empty during filtration |
E24 | OIL LEVEL SENSOR FAILED (Gas) | Oil level sensor failed. |
E25 | RECOVERY FAULT | Recovery time exceeded maximum time limit. |