Problem | Probable Causes |
Frypots won’t top off. | A. | Fryer temperature too low. |
B. | Oil is too cold. |
C.JIB out of oil (yellow light illuminated)
D.Service required error exists
7.2.5Bulk Oil System Problems
Corrective Action
A. Fryer temperature must be at setpoint.
B.Ensure that the oil in the JIB is above 70°F (21°C).
C.Ensure the JIB is not out of oil. Replace JIB and reset yellow LED. If problem persists call your ASA
for assistance.
D. Call your ASA for assistance.
Problem |
| Probable Causes |
| Corrective Action | ||
|
|
| A. | Power cycle fryer by disconnecting | ||
|
|
|
| and reconnecting | ||
|
|
|
| power cord. |
|
|
|
|
| B. | If a filtration or any other filter | ||
| A. | Incorrect setup procedure. |
| menu function is in | process or | |
|
| FILTER | NOW? | YES/NO, | ||
| B. | Another function is in process. |
| |||
JIB won’t fill. |
| CONFIRM YES/NO, or SKIM VAT | ||||
| C. | Dispose valve not completely closed. |
| are displayed, wait until the process | ||
| D. | Bulk oil tank is empty. |
| |||
|
| is complete and try again. | ||||
| E. | Solenoid, pump or switch issue. |
| |||
| C. | Ensure the dispose valve handle is | ||||
|
|
| ||||
|
|
|
| pushed fully closed. |
| |
|
|
| D. Call your bulk oil provider. | |||
|
|
| E. | Call you ASA for assistance. | ||
JIB or vat filling slow. | A. | Pump or line issues beyond the scope of | A. | Contact your bulk oil provider. | ||
| operator troubleshooting. |
|
|
|
| |
|
|
|
|
|
| |
|
|
| A. | Power cycle fryer by disconnecting | ||
|
|
| ||||
|
|
|
| and reconnecting | ||
| A. | Incorrect setup procedure. |
| power cord. |
|
|
Frypot won’t fill. | B. | Dispose valve not completely closed. | B. | Ensure the dispose valve handle is | ||
| C. | Bulk oil tank is empty. |
| pushed fully closed. |
| |
| D. | RTI pump issue. | C. Call your bulk oil provider. | |||
|
|
| D. Call you ASA for assistance. |
7.2.6Error Log Codes
Code | ERROR MESSAGE | EXPLANATION |
E03 | ERROR TEMP PROBE FAILURE | TEMP Probe reading out of range |
E04 | HI 2 BAD | High limit reading is out of range. |
E05 | HOT HI 1 | High limit temperature is past more than 410°F |
|
| (210°C), or in CE countries, 395°F (202°C) |
E06 | HEATING FAILURE | A component has failed in the high limit circuit |
|
| such as computer, interface board, contactor or |
|
| |
E07 | ERROR MIB SOFTWARE | Internal MIB software error |
E08 | ERROR ATO BOARD | MIB detects ATO board connection lost; ATO |
|
| board failure |
E09 | ERROR PUMP NOT FILLING | Dirty pad and it needs changed or it was |
|
| bypassed; filter pump problem |
E10 | ERROR DRAIN VALVE NOT OPEN | Drain valve was trying to open and confirmation |
|
| is missing |