6)Turn on the power supply, then move the power switch to the "ON" position. Blow out the evaporator drain line using the compressed air or carbon dioxide supply until water stops coming out.
7)Move the power switch to the "OFF" position, then turn off the power supply. Reconnect the evaporator drain line hose.
8)Replace the front panel in its correct position.
9)Remove all ice from the dispenser unit/storage bin. Clean the dispenser unit/storage bin liner using a neutral cleaner. Rinse thoroughly after cleaning.
3.On
1)Make sure the power supply is off, then remove the front and right side panels.
2)Close the condenser water supply line
3)Open the condenser water supply line drain valve. If connected to a closed loop system, also open the condenser return line drain valve.
4)Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve.
5)Open the water regulating valve by using a screwdriver to pry up on the spring retainer underneath the spring. While holding the valve open, blow out the condenser using the compressed air or carbon dioxide supply until water stops coming out.
6)Close the drain valve(s).
7)Replace the right side panel and front panel in their correct positions.
43