Hoshizaki FD-1001MRH(-C), FD-1001MLH(-C), FD-1001MAH(-C) FD-1001MRH-C remote air-cooled

Page 8

3. FD-1001MRH(-C) (remote air-cooled)

HOSHIZAKI ICE MAKER

MODEL NUMBER

FD-1001MRH

SERIAL NUMBER

208-230/60/1 (3 WIRE

AC SUPPLY VOLTAGE

COMPRESSOR

WITH NEUTRAL FOR 115V)

240V 4.2RLA 34LRA

GEAR MOTOR

120V 3.0FLA 1/4HP

FAN MOTOR

REMOTE 120V 3A MAX

OTHER

120V 0.53A

MAXIMUM FUSE SIZE

15

AMPS

MAX HACR BREAKER (USA ONLY)

15

AMPS

MAX CIRC BREAKER (CANADA ONLY)

15

AMPS

MINIMUM CIRCUIT AMPACITY

15

AMPS

DESIGN PRESSURE

HI-427PSI LO-230PSI

REFRIGERANT

 

404A

MOTOR-COMPRESSOR THERMALLY PROTECTED,

NOT INTENDED FOR OUTDOOR USE!

Hoshizaki America, Inc.

Peachtree City, GA

www.hoshizaki.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ICE MAKER WITHOUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STORAGE MEANS

COMPONENT

 

946Z

 

186090

Note: Only the "MODEL NUMBER" is replaced for FD-1001MRH-C.

See the nameplate for electrical and refrigeration specifications. This nameplate is located on the rear panel.

Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.

We reserve the right to make changes in specifications and design without prior notice.

Image 8
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page Important Safety Information Serious injuryIndicates important information about the use and care UnitSpecifications Nameplate Rating FD-1001MAH-C air-cooledFD-1001MWH-C water-cooled FD-1001MRH-C remote air-cooled FD-1001MLH-C low-side, parallel rack system Dimensions / Connections FD-1001MWH-C water-cooled FD-1001MRH-C remote air-cooled FD-1001MLH-C low side, parallel rack system II. Installation and Operating Instructions Checks Before InstallationHow to Remove Panels See FigSetup LocationAdditional Warnings for Remote Air-Cooled Model Electrical ConnectionFor All Models Location Installation of Remote Condenser UnitChecks Before Installation Setup Line SetField Fabricated Line Set Installation Polyol Ester POE OIL Electrical Connection Stacking Remote Condenser Units Line Set Installation Connection to an R-404A Parallel Rack SystemRack System-Braze Connection Entire Male Fitting Water Supply and Drain Connections See , 15, orFD-1001MAH-C FD-1001MRH-C FD-1001MLH-C IcemakerFD-1001MWH-C Condenser ConnectionTo a Potable Water SupplyClosed Loop FD-1001MWH-CConnection to Final Checklist Startup Bin Control Check Infrared Sensor CheckThumbscrew Infrared Sensor Housing Lens Mechanical Backup Bin Control Check Infrared Sensor Shutdown Delay Seconds 1.6 minutesIII. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Solution Cleaning ProcedureFloat Switch Assembly Reservoir Cover Infrared Sensor Infrared Sensor Housing Lens Sanitizing Solution Sanitizing Procedure InitialSanitizing Procedure Final Maintenance Frequency Area TaskDrain the evaporator Preparing the Icemaker for Long StorageRemove the water from the icemaker water supply line Page Hoshizaki AMERICA, INC