HOSHIZAKI ICE MAKER

MODEL NUMBER

FD-1001MWH

SERIAL NUMBER

208-230/60/1 (3 WIRE

AC SUPPLY VOLTAGE

COMPRESSOR

WITH NEUTRAL FOR 115V)

240V 4.2RLA 34LRA

GEAR MOTOR

120V 3.0FLA 1/4HP

FAN MOTOR

--- --- ---

OTHER

120V 0.03A

MAXIMUM FUSE SIZE

15

AMPS

MAX HACR BREAKER (USA ONLY)

15

AMPS

MAX CIRC BREAKER (CANADA ONLY)

15

AMPS

MINIMUM CIRCUIT AMPACITY

15

AMPS

DESIGN PRESSURE

HI-427PSI LO-230PSI

REFRIGERANT

404A 1 LB 1 OZ.

MOTOR-COMPRESSOR THERMALLY PROTECTED,

NOT INTENDED FOR OUTDOOR USE!

Hoshizaki America, Inc.

Peachtree City, GA

www.hoshizaki.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ICE MAKER WITHOUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

STORAGE MEANS

COMPONENT

 

946Z

 

186090

Note: Only the "MODEL NUMBER" is replaced for FD-1001MWH-C.

See the nameplate for electrical and refrigeration specifications. This nameplate is located on the rear panel.

Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.

We reserve the right to make changes in specifications and design without prior notice.

Image 7
Contents Superior Degree Reliability Hoshizaki AMERICA, INC Contents Page Unit Important Safety InformationSerious injury Indicates important information about the use and careFD-1001MAH-C air-cooled Specifications Nameplate RatingFD-1001MWH-C water-cooled FD-1001MRH-C remote air-cooled FD-1001MLH-C low-side, parallel rack system Dimensions / Connections FD-1001MWH-C water-cooled FD-1001MRH-C remote air-cooled FD-1001MLH-C low side, parallel rack system See Fig II. Installation and Operating InstructionsChecks Before Installation How to Remove PanelsLocation SetupFor All Models Electrical ConnectionAdditional Warnings for Remote Air-Cooled Model Checks Before Installation Installation of Remote Condenser UnitLocation Line Set SetupField Fabricated Line Set Installation Polyol Ester POE OIL Electrical Connection Stacking Remote Condenser Units Connection to an R-404A Parallel Rack System Line Set InstallationRack System-Braze Connection Entire Male Fitting See , 15, or Water Supply and Drain ConnectionsIcemaker FD-1001MAH-C FD-1001MRH-C FD-1001MLH-CWater Supply FD-1001MWH-C CondenserConnection To a PotableConnection to FD-1001MWH-CClosed Loop Final Checklist Startup Infrared Sensor Check Bin Control CheckThumbscrew Infrared Sensor Housing Lens Mechanical Backup Bin Control Check Seconds 1.6 minutes Infrared Sensor Shutdown DelayCleaning Procedure III. Cleaning and MaintenanceCleaning and Sanitizing Instructions Cleaning SolutionFloat Switch Assembly Reservoir Cover Infrared Sensor Infrared Sensor Housing Lens Sanitizing Procedure Initial Sanitizing SolutionSanitizing Procedure Final Frequency Area Task MaintenanceRemove the water from the icemaker water supply line Preparing the Icemaker for Long StorageDrain the evaporator Page Hoshizaki AMERICA, INC