C. Location
CAUTION
1.This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating water temperature should be within 45°F to 90°F (7°C to 32°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect icemaker performance.
2.This icemaker will not work at
For best operating results:
•The icemaker should not be located next to ovens, grills, or other high heat producing equipment.
•The location should provide a firm and level foundation for the equipment.
•Allow 6" (15 cm) clearance at rear and sides for proper air circulation and ease of maintenance and/or service should they be required. Allow 24" (61 cm) clearance at top to allow for removal of the auger.
D.Setup
1)If mounting the icemaker on top of a dispenser unit, first follow the dispenser unit's setup procedure. Note that only cubelet models can be installed on a dispenser unit; flaker models cannot be installed on a dispenser unit. If mounting the icemaker on top of a storage bin, unpack the storage bin, and attach the 4 adjustable legs provided (bin accessory) to the bottom of the storage bin.
2)Position the dispenser unit/storage bin in the selected permanent location.
3)Place the icemaker on top of the dispenser unit/storage bin.
4)Secure the icemaker to the dispenser unit/ storage bin using the 2 mounting brackets and the bolts provided. See Fig. 2.
5)Level the icemaker and dispenser unit/ storage bin in both the
6)Replace the panels in their correct positions.
Mounting Brackets
Bolts
Icemaker
Storage Bin
Fig. 2