PRODUCT DATA SHEETS

Interior Water Filtration System

Model UFK8001AXX-750 Capacity 750 Gallons (2839 Liters)

System tested and certified by NSF International against NSF/ANSI

Standard 42 for the reduction of Chlorine Taste and Odor, Particulate

Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead,

Mercury, Atrazine, Benzene, p-Dichlorobenzene, Carbofuran,

Toxaphene, Cysts, Turbidity, Asbestos and Lindane.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50% reduction

1.88 mg/L

2.0 mg/L ± 10%

0.06 mg/L

0.05 mg/L

96.84

>97.26

Particulate Class I*

85% reduction

5,700,000 #/mL

At least 10,000

69,000 #/mL**

30,583 #/mL

98.94

99.52

 

 

 

particles/mL

 

 

 

 

 

 

 

 

 

 

 

 

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

0.010 mg/L

0.153 mg/L

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

>99.29%

>99.35%

Lead: @ pH 8.5

0.010 mg/L

0.150 mg/L

0.15 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

>99.29%

>99.33%

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.0005 mg/L

0.0003 mg/L

90.91

95.70

Mercury: @ pH 8.5

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

0.0015 mg/L

0.0008 mg/L

75.93

86.22

 

 

 

 

 

 

 

 

Benzene

0.005 mg/L

0.014 mg/L

0.015 mg/L ± 10%

0.0011 mg/L

0.0006 mg/L

92.14%

95.71%

 

 

 

 

 

 

 

 

p-Dichlorobenzene

0.075 mg/L

0.208 mg/L

0.225 mg/L ± 10%

< 0.0005 mg/L

< 0.0005 mg/L

99.74%

99.76%

 

 

 

 

 

 

 

 

Carbofuran

0.04 mg/L

0.081 mg/L

0.08 mg/L ± 10%

< 0.001mg/L

< 0.001mg/L

98.46%

98.74%

 

 

 

 

 

 

 

 

Toxaphene

0.003 mg/L

0.015 mg/L

0.015 ± 10%

< 0.001mg/L

< 0.001mg/L

91.67%

92.97%

 

 

 

 

 

 

 

 

Atrazine

0.003 mg/L

0.009mg/L

0.009 mg/L ± 10%

< 0.002 mg/L

< 0.002 mg/L

75.31%

76.99%

 

 

 

 

 

 

 

 

Asbestos

99%

155 MF/L

107 to 108 fibers/L††

< 1 MF/L

< 1 MF/L

>99.99%

>99.99%

 

 

 

 

 

 

 

 

Live Cysts

>99.95%

166,500 #/L

50,000/L min.

< 1 #/L

< 1 #/L

>99.99

>99.99

Turbidity

0.5 NTU

10.7 NTU

11 ± 1 NTU

0.49 NTU

0.31 NTU

95.2

97.09

 

 

 

 

 

 

 

 

Lindane

0.0002 mg/L

0.002 mg/L

0.002 ± 10%

< 0.0001mg/L

0.000 mg/L

96.50%

98.72%

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C).

It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the yellow (Order) light comes on. When 100% of the filter’s rated life is used, the red (Replace) light comes on, and it is recommended that you replace the filter. For models without filter status lights, replace the filter every 6 months. Use replacement filter model UFK8001AXX-750. 2007 suggested retail price of $49.99 U.S.A./$65.95 Canada. Prices are subject to change without notice.

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Refer to the “Water Filtration System” section for the Manufacturer’s name and telephone number.

Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

35 - 120 psi (241 - 827 kPa)

Water Temperature

33° - 100°F (1° - 38°C)

Service Flow Rate

0.78 gpm (2.9 L/min.) @ 60 psi

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ††Fibers greater than 10 um in length

Based on the use of Cryptosporidium parvum oocysts ® NSF is a registered trademark of NSF International.

16

Image 16
Contents Refrigerator Safety Refrigerator User InstructionsInstallation Instructions Clean Before UsingUnpack the Refrigerator Before You Throw Away Your Old Refrigerator or FreezerLocation Requirements Electrical RequirementsWater Supply Requirements Recommended Grounding MethodConnect the Water Supply Water PressureReverse Osmosis Water Supply Connect to Water LineComplete the Installation Refrigerator Doors and DrawerRemove and Replace Handles Style 1 Metal Handles Style 2 Plastic HandlesReplace Doors and Hinges Remove and Replace Freezer DrawerRemove Drawer Front Replace Drawer FrontDrawer Front Removal Drawer Front Replacement Adjust the Doors Refrigerator USEOpening and Closing Doors Style 1 Front and rear levelingUsing the Controls Crisper Humidity Control Water and Ice Dispenser Dispense Ice and WaterRefrigerator Care CleaningWater Filtration System Troubleshooting Changing the Light BulbRefrigerator Operation Refrigerator will not operateTemperature and Moisture Ice and WaterWater Filter Certifications Water and ice dispenser will not operate properlyWater is leaking from the dispenser system Water from the dispenser is warmProduct Data Sheets Application Guidelines/Water Supply ParametersMaytag Major Appliance Warranty Limited WarrantyItems Excluded from Warranty This limited warranty does not coverInstrucciones Para EL Usuario DEL Refrigerador Seguridad DEL RefrigeradorDesempaque el refrigerador Instrucciones DE InstalaciónRequisitos de ubicación Requisitos del suministro de agua Requisitos eléctricosMétodo de conexión a tierra recomendado Presión del aguaConexión a la línea de agua Conexión del suministro de aguaConexión al refrigerador Puertas y cajón del refrigerador Complete la instalaciónEstilo 2 Agarraderas de plástico Cómo quitar las puertas y las bisagrasCómo volver a poner las puertas y las bisagras en su lugar Cómo quitar y volver a colocar el cajón del congeladorPara quitar el frente del cajón Para volver a colocar el frente del cajónCómo quitar la puerta y cambiarla USO DE SU Refrigerador Ajuste las puertasCómo abrir y cerrar las puertas Estilo 1-Nivelación delantera y traseraUso de los controles Controles de temperaturaCómo ajustar los controles Para regular temperaturas de punto de ajusteDoor Alarm Alarma de la puerta Vacation Mode Modo de vacaciones en algunos modelosTemp Alarm Alarma de temperatura Alarma ALDespachador de agua y hielo Para encender y apagar la fábrica de hieloPara volver a colocar el depósito de hielo Ritmo de producción de hieloSistema de filtración de agua Cuidado DE SU Refrigerador LimpiezaCómo cambiar el foco Para limpiar su refrigeradorSolución DE Problemas Funcionamiento del refrigeradorTemperatura y humedad Hielo y aguaEl despachador de agua y hielo no funciona debidamente Hay fugas de agua en el sistema del despachadorEl agua del despachador está tibia ¿Está la presión de agua a por lo menos 35 lbs/pulg²Hoja DE Datos DEL Producto Pautas de aplicación/Parámetros para el suministro de aguaMaytag Garantía LimitadaExclusiones DE LA Garantía Esta garantía limitada no cubreInstructions Dutilisation DU Réfrigérateur Sécurité DU RéfrigérateurExigences demplacement Instructions D’INSTALLATIONDéballage du réfrigérateur Méthode recommandée de mise à la terre Spécifications de l’alimentation en eauSpécifications électriques Pression de leauRaccordement à une canalisation d’eau Raccordement de la canalisation deauRaccordement au réfrigérateur Achever l’installation Portes et tiroir du réfrigérateurStyle 2 Poignées en plastique Enlèvement de la porte et des charnièresRéinstallation des portes et des charnières Retirer et réinstaller le tiroir du congélateurRéinstallation de la façade du tiroir Enlèvement de la façade du tiroirEnlèvement et réinstallation de la porte Utilisation DU Réfrigérateur Ajustement des portesOuverture et fermeture des portes Style 1-Nivellement avant et arrièreUtilisation des commandes Commandes de températureAjustement des commandes Pour ajuster les réglages de températureHumidity Control commande dhumidité sur certains modèles Door Alarm avertisseur de la porteVacation Mode mode vacances sur certains modèles Temp Alarm alarme de dépassement de températurePour réinstaller le bac d’entreposage à glaçons Distributeur d’eau et de glaçonsMise en marche/arrêt de la machine à glaçons Taux de production de glaçonsSystème de filtration de leau Remplacement de l’ampoule d’éclairage Entretien DU RéfrigérateurNettoyage Nettoyage de votre réfrigérateurDépannage Fonctionnement du réfrigérateurTempérature et humidité Glaçons et eau’eau coule du système de distribution Leau du distributeur est tièdeFeuilles DE Données SUR LE Produit Système de filtration d’eau intérieurArticles Exclus DE LA Garantie Garantie LimitéeLa présente garantie limitée ne couvre pas W10175477A EN/FR PN W10175444A