Installation Instructions
B3 New Construction and
Four-Conductor Branch
Circuit Connection
•When installing in new construction, or
•When installing in a mobile home, or
•When installing in a recreational vehicle, or
•When local codes do not permit grounding through neutral:
a. Cut the neutral (white) lead from the crimp.
Ground
Wire
Junction Box
Cover
b. Attach the appliance grounding lead (green or bare copper) in accordance with local codes. If the residence grounding conductor is aluminum, see WARNING on page 14.
c. Connect the oven neutral (white) lead to the branch circuit neutral (white or gray) in accordance with local codes, using a wire nut.
d. Connect the oven red lead to the branch circuit red lead and the oven black lead to the branch circuit black lead in accordance with local codes, using wire nuts. If the residence red, black or white leads are aluminum conductors, see WARNING
on page 14.
e. Install Junction Box Cover.
B4 Three-Conductor Branch Circuit Connection
When connecting to a
a. Connect the bare oven ground conductor with the crimped neutral (white) lead to the branch circuit neutral (white or gray in color), using a wire nut.
Ground and
Neutral Wires
Junction Box
Cover
b. Connect the oven red lead to the branch circuit red lead in accordance with local codes, using a wire nut.
c. Connect the oven black lead to the branch circuit black lead in accordance with local codes, using a wire nut. If the residence red, black or white leads are aluminum conductors, see WARNING on page 14.
d. Install Junction Box Cover.