VENTING

Pressure regulators contain an air vent in the upper chamber to allow a free flow of air in and out of the chamber during operation (see Figure 2-7). The vent’s secondary purpose is to safely control the flow of gas to the atmosphere (200cc-per-hour or 7 BTU-per-hour) in case the diaphragm ruptures. If the vent is partially or completely plugged, the regulator will become sluggish. It can also become fixed in the high or low position, depending on which position the diaphragm was in when it became plugged.

Vent (Through

Hole In Cap)

Cap

Figure 2-7

REGULATOR DIAGNOSTICS

Common causes for regulator failure are:

A. Ruptured diaphragm.

B. Broken or worn valve.

C. Debris accumulating around the valve seat.

D. Restricted (plugged) vent.

E.Internal corrosion due to water in the L.P. gas system. Keep the tank full to prevent this from occurring.

As a safety feature, the regulator will “lock-up” and restrict all gas flow during any situation that applies extreme pressure to the incoming gas supply line. The pressure regulator can be unlocked by removing the cap, and pushing down on the diaphragm with the eraser end of a pencil.

Usually the appliance regulator is replaced rather than serviced, since it has few replaceable or serviceable parts, and is a relatively inexpensive device.

Page 2-4

Image 16
Contents GAS Ranges Voltage Checks Table Of Contents Page Introduction Page Fundamental Properties of GAS Measuring Heat EnergyFuel Types #2 Mixed GAS#3 Manufactured GAS #4 Liquefied Petroleum L.P. GASCategory Characteristics of GAS Fuels FuelDistribution of Natural GAS 25 To 60 Pounds Pressure MainDistribution of L.P. GAS Pressure Regulators FunctionsRegulator Operation Open Position Regulator Diagnostics VentingMeasuring GAS Pressure WHIRLPOOL, U.S.A., Benton HARBOR, MIMagnehelic Gauge Cooktop Burner System GAS DistributionGAS Valve OFF PositionGAS Valve Orifices PLUG-TYPE OrificesOrifice Specifications Chart Natural GAS OrificesUniversal ORIFICE-OVEN Application Natural Gas PositionGAS Valve Orifice Diagnostics Performance Check Burner Operation AIR Shutter & Venturi Burner Head Flame Characteristics Properly Burning FlameNot Enough Primary Air Flame Quenching Page Improper Flame Diagnostics Symptom Cause Corrective ActionCleaning the Burners Port Burner Climber PortStanding Pilot Ignition System OperationRelighting a Standing Pilot Adjusting the Pilot Flame Height Cleaning the Pilot Electronic Ignition System 123Ground Strap Ignitor Spark Sealed Burner FlowElectronic Ignition Diagnostics Performance Check Oven Burner System Standing Pilot IgnitionGas Standing Pilot Safety Valve Lighting the Oven Pilot GLO-BAR Ignition Thermostat Switch Contacts Oven Ignitor Safety Valve 50 to 1100 Ω Amps Safety Valve Thermostat Switch Contacts Oven Ignitor Safety Valve Cleaning the Oven Burner SELF-CLEANING System 88PBK P3-1 P3-4 Oven Off Bake Cycle Broil Cycle Bake BroilCode Guidelines F0 =Performance Check SELF-CLEAN Oven Door Locking System Door Locked Door Unlocked Natural and L.P. GAS Conversion GeneralConverting a Pressure Regulator Converting Cooktop BurnersConverting AN Oven Burner Converting AN Oven ThermostatBurner Flame Adjustment Performance Check Page Testing the Components General Information Testing AN Oven GLO-BAR Igniter Carborundum IgnitorTesting AN Ignitor Switch Offoff LiteliteTesting AN Oven Light Switch Testing AN Oven Temperature Sensor Testing AN Oven Door Latch To test the solenoid windings, perform the following stepsTo test the switches Testing a GAS Safety Valve Testing the GAS Control Valves Testing the GAS Pressure Regulator Manual Shutoff ValveTroubleshooting Chart Problem Possible Cause SolutionProblem Possible Cause Solution Schematic Diagrams Standard RangeSelf-Clean Range Strip Circuits BakeOven Light