Whirlpool 4322452 manual GAS Valve Orifices, PLUG-TYPE Orifices

Page 21

GAS VALVE ORIFICES

An orifice is an opening used to control the direction and amount of gas that is discharged to a burner. Orifices are available in different sizes and shapes and can be removed and replaced without replacing the valve.

PLUG-TYPE ORIFICES

The cooktop burner orifice uses a plug-typeorifice, as shown in Figure 3-5. The orifice is generally constructed of brass, and consists of a threaded seat, a chamber, and a metered hole. The threaded seat allows the orifice to be securely fastened to the burner valve. The chamber is used as a passageway to allow gas to flow through the orifice opening. The orifice is used to control, or limit, the amount of gas going to the burner. This type of orifice is not adjustable.

Natural Gas

 

Orifice Drill Size No.

Orifice Opening

(Stamped On Top)

 

Orifice

Gas Flow

 

Out

55

 

Threaded Seat

Gas Flow

In

Chamber

Threaded Seat

L.P. Gas

Orifice Drill Size No.

(Stamped On Top)

Orifice

Orifice

Gas Valve

 

65

 

 

Figure 3-5

L.P. Gas

Identification

Notch In Orifice Cap

Threaded Seat

Page 3-3

Image 21
Contents GAS Ranges Voltage Checks Table Of Contents Page Introduction Page Measuring Heat Energy Fundamental Properties of GAS#2 Mixed GAS Fuel Types#3 Manufactured GAS #4 Liquefied Petroleum L.P. GASCategory Fuel Characteristics of GAS Fuels25 To 60 Pounds Pressure Main Distribution of Natural GASDistribution of L.P. GAS Functions Pressure RegulatorsRegulator Operation Open Position Venting Regulator DiagnosticsWHIRLPOOL, U.S.A., Benton HARBOR, MI Measuring GAS PressureMagnehelic Gauge GAS Distribution Cooktop Burner SystemOFF Position GAS ValvePLUG-TYPE Orifices GAS Valve OrificesNatural GAS Orifices Orifice Specifications ChartNatural Gas Position Universal ORIFICE-OVEN ApplicationGAS Valve Orifice Diagnostics Performance Check Burner Operation AIR Shutter & Venturi Burner Head Properly Burning Flame Flame CharacteristicsNot Enough Primary Air Flame Quenching Page Symptom Cause Corrective Action Improper Flame DiagnosticsPort Burner Climber Port Cleaning the BurnersOperation Standing Pilot Ignition SystemRelighting a Standing Pilot Adjusting the Pilot Flame Height Cleaning the Pilot 123 Electronic Ignition SystemGround Strap Ignitor Spark Flow Sealed BurnerElectronic Ignition Diagnostics Performance Check Standing Pilot Ignition Oven Burner SystemGas Standing Pilot Safety Valve Lighting the Oven Pilot GLO-BAR Ignition Thermostat Switch Contacts Oven Ignitor Safety Valve 50 to 1100 Ω Amps Safety Valve Thermostat Switch Contacts Oven Ignitor Safety Valve Cleaning the Oven Burner 88P SELF-CLEANING SystemBK P3-1 P3-4 Oven Off Bake Cycle Broil Cycle Broil BakeF0 = Code GuidelinesPerformance Check SELF-CLEAN Oven Door Locking System Door Locked Door Unlocked General Natural and L.P. GAS ConversionConverting Cooktop Burners Converting a Pressure RegulatorConverting AN Oven Thermostat Converting AN Oven BurnerBurner Flame Adjustment Performance Check Page Testing the Components General Information Carborundum Ignitor Testing AN Oven GLO-BAR IgniterOffoff Litelite Testing AN Ignitor SwitchTesting AN Oven Light Switch Testing AN Oven Temperature Sensor To test the solenoid windings, perform the following steps Testing AN Oven Door LatchTo test the switches Testing a GAS Safety Valve Testing the GAS Control Valves Manual Shutoff Valve Testing the GAS Pressure RegulatorProblem Possible Cause Solution Troubleshooting ChartProblem Possible Cause Solution Standard Range Schematic DiagramsSelf-Clean Range Bake Strip CircuitsOven Light