TESTING AN IGNITOR SWITCH
The ignitor switch (see Figure
1.Turn off the gas and electrical power to the range.
2.Disconnect the wires from the ignitor switch terminals.
3.Set the ohmmeter to the R x 1 position.
4.With the control knob in the OFF position, touch the meter leads to the switch terminals. The meter should indicate no continuity.
OFFOFF
LITELITE
Control OFF | Control Set To Lite |
Switch Open | Switch Closed |
| Figure |
Figure 6-3A
5.Turn the control knob to the LITE position, and the meter should indicate continuity. If the readings are not as indicated in the test, replace the switch.