Whirlpool 4322452 manual Testing the GAS Pressure Regulator, Manual Shutoff Valve

Page 81

TESTING THE GAS PRESSURE REGULATOR

The pressure regulator is a mechanical device that reduces the higher incoming gas pressure to a lower outgoing pressure, and maintains a steady, even flow of gas.

The pressure regulator has one outlet that is connected directly to the gas safety valve. The inlet has a manual shutoff valve so that the gas to the safety valve can be turned off (see Figure 6-13).

PRESSURE

REGULATOR

Manual Shutoff Valve

Figure 6-13

 

The common causes of pressure regulator failure are:

a)Ruptured diaphragm.

b)Broken or weak valve.

c)Accumulated debris around the valve seat.

d)Plugged vent.

The pressure regulator is normally replaced rather than serviced, since it has few replaceable or serviceable parts, and is a relatively inexpensive device.

Use a manometer, or a magnehelic gauge, to test the pressure regulator.

Natural Gas = 4" WCP

L.P. Gas = 11" WCP

If the reading is not within the range shown, the pressure regulator is defective and should be replaced.

Page 6-11

Image 81
Contents GAS Ranges Voltage Checks Table Of Contents Page Introduction Page Measuring Heat Energy Fundamental Properties of GAS#2 Mixed GAS Fuel Types#3 Manufactured GAS #4 Liquefied Petroleum L.P. GASCategory Fuel Characteristics of GAS Fuels25 To 60 Pounds Pressure Main Distribution of Natural GASDistribution of L.P. GAS Functions Pressure RegulatorsRegulator Operation Open Position Venting Regulator DiagnosticsWHIRLPOOL, U.S.A., Benton HARBOR, MI Measuring GAS PressureMagnehelic Gauge GAS Distribution Cooktop Burner SystemOFF Position GAS ValvePLUG-TYPE Orifices GAS Valve OrificesNatural GAS Orifices Orifice Specifications ChartNatural Gas Position Universal ORIFICE-OVEN ApplicationGAS Valve Orifice Diagnostics Performance Check Burner Operation AIR Shutter & Venturi Burner Head Properly Burning Flame Flame CharacteristicsNot Enough Primary Air Flame Quenching Page Symptom Cause Corrective Action Improper Flame DiagnosticsPort Burner Climber Port Cleaning the BurnersOperation Standing Pilot Ignition SystemRelighting a Standing Pilot Adjusting the Pilot Flame Height Cleaning the Pilot 123 Electronic Ignition SystemGround Strap Ignitor Spark Flow Sealed BurnerElectronic Ignition Diagnostics Performance Check Standing Pilot Ignition Oven Burner SystemGas Standing Pilot Safety Valve Lighting the Oven Pilot GLO-BAR Ignition Thermostat Switch Contacts Oven Ignitor Safety Valve 50 to 1100 Ω Amps Safety Valve Thermostat Switch Contacts Oven Ignitor Safety Valve Cleaning the Oven Burner 88P SELF-CLEANING SystemBK P3-1 P3-4 Oven Off Bake Cycle Broil Cycle Broil BakeF0 = Code GuidelinesPerformance Check SELF-CLEAN Oven Door Locking System Door Locked Door Unlocked General Natural and L.P. GAS ConversionConverting Cooktop Burners Converting a Pressure RegulatorConverting AN Oven Thermostat Converting AN Oven BurnerBurner Flame Adjustment Performance Check Page Testing the Components General Information Carborundum Ignitor Testing AN Oven GLO-BAR IgniterOffoff Litelite Testing AN Ignitor SwitchTesting AN Oven Light Switch Testing AN Oven Temperature Sensor To test the solenoid windings, perform the following steps Testing AN Oven Door LatchTo test the switches Testing a GAS Safety Valve Testing the GAS Control Valves Manual Shutoff Valve Testing the GAS Pressure RegulatorProblem Possible Cause Solution Troubleshooting ChartProblem Possible Cause Solution Standard Range Schematic DiagramsSelf-Clean Range Bake Strip CircuitsOven Light