Garland MP-GS, MP-GD-10-S service manual Temperature Calibration

Page 33

TEMPERATURE CALIBRATION

1.Press and hold “PROGRAM” Button for three (3) seconds.. When prompted, enter the Diagnostics Code 3-4-2-4, Press “Y”.. The Moisture Plus part number will display briefly followed by the Diagnostic Tests – Keypad Test..

2.Press the “N” Button to scroll to Diagnostic Tests – Temp Cal.. Press “Y”..

3After selecting Temperature Calibration and Pressing “ENTER”.. The display will show the Actual Temperature inside the oven.. Verify the cavity temperature using a pyrometer..

4. Press and hold the “PHANTOM” button for three, (3), seconds.. The display will show the Actual Temperature on the first line and Set Temperature on the second line.. If the Actual Temperature does not correspond to the pryometer, enter the value on the pyromter using buttons 1 – 0.. The value will be input as Set Temp..

5.Press “Y” to accept the changes.. The actual Temperature will change to equal the value input for Set Temperature.. Press Cancel to exit Temperature Calibration..

NOTE: After the desired Tests are completer, press “PROGRAM” to exit Diagnostics Mode..

Part # MPSM07 (03/24/08)

Page 33

Image 33 Contents
Models MP-GS/GD-10-S MPSM07 03/24/08 Table of Contents MPSM07 03/24/08 Section One Operation Installation Manual MPSM07 03/24/08 Inlet Hour Dimensions and SpecificationsLegs and Casters Preparing the Oven for InstallationInner Outer Open Base AssemblyItem Description Stacking Two OvensGAS Connections InstallationLocation Wall ClearanceElectrical Connections Water Quality Requirements Water ConnectionsSpray/Flex Hose W/Quick Disconnect DrainVentilation and AIR Supply Installation of a Direct VentTo Conserve Energy GAS Model Testing & Lighting InstructionsFan Speed Switch Moisture SwitchPower Switch Light SwitchStart Up Off ModeFan Speed Interior LightOn/Off DisplayLight MoistureHigh Fan Start/CancelLow Fan Pulse FanProgrammable Control Deluxe Models Changing the Temperature Scale, F or CStart-Up Auto Cool Down And Cool DownProgram Moisture Using Cook & HoldCooking With a Core Probe Programming Recipe Keys System Program OptionsTo program a recipe key Using the Shelf Timer Feature To program shelf timersCooking With a Recipe Key Display Messages Cooking with shelf timersMPSM07 03/24/08 Page MPSM07 03/24/08 Cooking with Moisture User Moisture Settings Mechanical Control, Standard Models Programmable Control, Deluxe ModelsMoisture + Cooking Guide Product TempTime Deluxe Control Standard Control Kaiser Rolls Performance Recommendations About Moisture PresetsTemperature Calibration Problems / Solutions ProblemSolution Exterior Cleaning CleaningInterior Cleaning Fan Area CleaningMaintenance Motor CareWater System Replacement Parts MPSM07 03/24/08 Section Two Service Moisture Control Mechanical Moisture Control Component IdentificationWater pressure check Deluxe Fast Panel Moisture ControlService Overview Cavity Temperature ControlsControl Compartment Ambient Temperature Spritzer Water InletSolid State control Heat Control Transformer Diagnostics Mode Diagnostic ProceduresDoor Switch Test Proper Door Switch ActivationControl Safety Features Temperature CalibrationFan Speed Test Heat TestDiagnostic Procedures Testing & Troubleshooting Mechanical ControlFast Control OK? Key Ribbon Test Points Key Pad / Ribbon Connector Test PointsRelay Board Component Identification Relay BoardRelay Relay Output Inputs Outputs Function Test Point Test PointsFan Motor And Blower Wheel Component ReadingsDual Stage Gas Valve Solenoid Resistance Direct Spark Ignition ModuleJohnson Controls INC ManufacturerWiringdiagrams Wiring Diagrams Service Procedures REMOVAL/REPLACEMENT Oven Door Service Removal / InstallationOven Door Light Service / Removal Remove both screws.. do not Touch the Countersink Screw Oven Temperature Probe Service/RemovalDoor To Cavity Seal Adjustments RH Door Frame To Cavity Seal AdjustmentMPSM07 03/24/08 Section Three Parts List Moisture Plus GAS Electronic Deluxe Control Panel Gas Garland Parts IdentificationStandard Control Panel Description Quantity UP to From Standard Control Panel Mechanical ControlBurners & GAS Components Burner & Gas Components Moisture Plus GAS Interior Components Gas MPSM07 03/24/08 Moisture +Description QTY UP to From Door ComponentsMoisture + 1934501 Valve-regulator Plumbing Components GasMoisture Plus 1926501 Caster 4 Screw 1926502 Caster 4 With Brake Screw Main ExteriorWire Diagrams Wire Diagrams & HarnessesWire Harness ModelMPSM07 03/24/08 MPSM07 03/24/08 MPSM07 03/24/08