TEMPERATURE CALIBRATION
1.Press and hold “PROGRAM” Button for three (3) seconds.. When prompted, enter the Diagnostics Code
2.Press the “N” Button to scroll to Diagnostic Tests – Temp Cal.. Press “Y”..
3After selecting Temperature Calibration and Pressing “ENTER”.. The display will show the Actual Temperature inside the oven.. Verify the cavity temperature using a pyrometer..
4. Press and hold the “PHANTOM” button for three, (3), seconds.. The display will show the Actual Temperature on the first line and Set Temperature on the second line.. If the Actual Temperature does not correspond to the pryometer, enter the value on the pyromter using buttons 1 – 0.. The value will be input as Set Temp..
5.Press “Y” to accept the changes.. The actual Temperature will change to equal the value input for Set Temperature.. Press Cancel to exit Temperature Calibration..
NOTE: After the desired Tests are completer, press “PROGRAM” to exit Diagnostics Mode..