Maytag CPL1110ADH/L/T, CPL1100ADH/L/Q/T/W manual Spark module Test for voltage at terminals 120 VAC

Page 15

Component Testing Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.

Illustration

Component

Test Procedure

Results

 

Spark module

Test for voltage at terminals

 

 

4 + 0

L and N

120 VAC

GND

Input

Polarity and ground

Not subject to polarity

L or N

 

 

 

Spark module

Test for voltage at terminals

120 VAC

 

2 + 0

 

 

 

CGL1100AD*

Polarity and ground

Not subject to polarity

 

Holder orifice

Verify gas pressure (WCP)

4" Natural

 

 

Check orifice for debris

10" LP/Propane

 

 

Clean as needed.

 

Shut-off Valve

Verify gas supply is turned on.

Gas is turned on.

 

Shut-off Valve

Verify gas supply is turned on.

Gas is turned on.

 

Model CPL1100AD*

 

 

 

270° valve

Verify gas is supplied.

 

 

 

Orifice adjusted for Natural or LP.

 

 

 

Adjust set screw for simmer control

Refer to LP/Nat. conversion instructions.

 

Spark 270° switch

Unplug switch harness at rear of

120 VAC

 

 

range. Test for continuity at wire

 

 

 

terminals.

 

 

 

Switch in LITE position

Continuity

 

 

Switch in any other position

Infinite

 

Spark switch

Unplug switch harness at rear of

120 VAC

 

Model CGL1100AD*

range. Test for continuity at wire

 

 

 

terminals.

 

 

 

Switch in LITE position

Continuity

 

 

Switch in any other position

Infinite

 

Sealed burner

Verify gas is supplied

Gas present.

 

 

Check for obstructions or

 

 

 

contamination in burner ports

Clean/remove any foreign objects.

 

 

 

Check ignitor for bending/cracking.

 

Open burner

Verify gas is supplied

Gas present.

 

Model CPR1100AD*,

 

 

 

LPR1115AD*,

Verify air shutter adjusted properly

Air shutter opening: .400" to .500".

 

CP31200AD*,

 

 

 

CG31200AD*

 

 

 

Open burner

Verify gas is supplied

Gas present.

 

Models CPL1100AD*,

 

 

 

CGL1100AD*

Verify air shutter adjusted properly

Air shutter opening: .435" to .565".

 

Open burner

Verify gas is supplied

Gas present.

 

Model CGR1110AD*

 

 

 

 

Verify air shutter adjusted properly

Air shutter opening: .420" to .460".

 

Pilot burner

Verify pilot selector cartridge is set to

 

 

Models CPL1100AD*,

the proper gas

LP or Natural

 

CPR1100AD*,

 

 

 

LPR1115AD*,

 

 

 

CP31200AD*,

 

 

 

CG31200AD*

 

 

©2004 Maytag Services

16023522

15

Image 15
Contents Service Important Information Customer Service Support CenterTable of Contents Servicing Safety Practices for ServicerReceiving Oven Using the OvenElectrical Requirements Connecting Range to GasProduct Safety Devices Baking, Broiling, and RoastingGeneral Information Parts and Accessories SpecificationsPlacement of the Oven ServiceGrounding ArningRange Description Troubleshooting Procedures Problem Possible Cause Correction Oven light does not operate Component Testing Procedures Spark module Test for voltage at terminals 120 VAC Seconds of powering up the unit Quick Test Mode for Electronic Range Control Sensor resistance Infinite Ohms Bake flashes Typical M1 Control Control Board Assembly Maintop AssemblyRocker Switch Top Surface Valve and Spark SwitchOven Sensor Valve / Regulator AssemblyManual Oven Door Latch Assembly Open BurnerStorage Drawer Removal Oven Door Hinge ReceiverSide Panel Removal BackguardOven Light Assembly Frameless Door Disassembly Large and Standard WindowsPower Cord Large Window Frameless Oven DoorOven Door No Window Door Disassembly No WindowAppendix a Installation Instructions Models CP31200AD*, CG31200AD 200 BTU/HR or Less Inches Installation Drawings Installation Drawings Installation Instructions Model LPR1115AD 200 BTU/HR or Less Inches 16023522 200 BTU/HR or Less Inches Appliance Pressure Regulator Alternate Connectors Flame 16023522 Appendix B Use Instructions Models CP/CG31200AD*, CPL1100AD*, CGL1100AD Use Instructions Models CP/CG31200AD*, CPL1100AD*, CGL1100AD Surface Cooking Oven Cooking Self-Clean Oven Control select models Pilotless Ignition E F To change the clock to Hour format Care & Cleaning Do not USE ANY Cleaning Product Containing Chlorine Bleach Appendix C Conversion Instructions Models CP31200AD*, CG31200AD Conversion Instructions Models CP31200AD*, CG31200AD GAS Conversion Gas Conversion Orifice Conversion Range Adjustments Conversion Instructions Model LPR1115AD 03-04-00 16023522 Orifice Hood Gas Conversion Orifice Conversion Surface Burner Conversion Conventional Air Shutter