Component Testing Procedures
!WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power and gas to oven before servicing, unless testing requires power and/or gas.
Illustration | Component | Test Procedure | Results |
| Oven light socket | Test continuity of receptacle terminals ... | Indicates continuity with bulb inserted. |
|
| Measure voltage at oven light | 120 VAC, see wiring diagram for terminal |
|
|
| identification. |
|
|
| If no voltage present, check wiring. |
| Rocker switch | Measure continuity of switch positions: |
|
|
| Closed | Continuity |
|
| Open | Infinite |
| Door lock switch | Switch connection in following | Normally Open |
NC |
| positions: Not engaged | |
COM |
| ||
NO |
|
|
|
|
| Engaged | |
| Manual Latch | Disconnect wires and test for |
|
| assembly with switch | continuity per wiring diagram | See wiring diagram for schematic layout. |
|
|
| Refer to Parts Manual for replacement |
|
|
| components. |
|
|
| NOTE: Control will cancel function if |
|
|
| latch is moved to LOCK position during |
|
|
| Bake or Broil. |
| Bake burner | Verify gas is supplied. | Air shutter opening: .469" to .531". |
|
| Verify proper orifice | Blue flame with no yellow tipping. |
|
| Check for obstructions, contamination |
|
|
| in ports or damage | Replace if punctured or torn. |
| Bake burner | Verify gas is supplied. | Air shutter opening: .349" to .411". |
| Models CPL1100AD*, | Verify proper orifice | Blue flame with no yellow tipping. |
| CGL1100AD* | Check for obstructions, contamination |
|
|
| in ports or damage | Replace if punctured or torn. |
| Broil burner | Verify gas is supplied. | Air shutter opening: .281" to .343". |
|
| Verify proper orifice | Blue flame with no yellow tipping. |
|
| Check for obstructions, contamination |
|
|
| in ports or damage | Replace if punctured or torn. |
| Ignitor | Test for voltage at terminals | 120 VAC |
|
| Test for amount of amperage in circuit ... | 3.2 to 3.6 Amps. |
|
| (Ignitor may glow, but not have |
|
|
| sufficient amperage to open valve). |
|
| Temperature sensor | Measure resistance | Approximately 1000 Ω at room |
|
|
| temperature 80°F. |
| Gas thermostat | Test for voltage at terminals | 120 VAC |
| Models AGR4400AD*, |
|
|
| CGR1415AD*, |
|
|
| CGR1110AD*, |
|
|
| CGL1100AD*, |
|
|
| CPL1100AD*, |
|
|
| CP31200AD*, |
|
|
| CG31200AD*, |
|
|
| CG31400AD* |
|
|
| Gas thermostat | Test for voltage at terminals | 120 VAC |
| Model CPR1100AD* |
|
|
| Pressure regulator | Verify gas pressure (WCP) | 4" Natural |
|
| If using LP service, verify proper gas | 10" LP/Propane |
|
|
| |
|
| supply conversion. |
|
| Spark ignition | Test for resistance of spark lead | Continuity |
| electrode |
|
|
|
| Test ignitor to chassis | No continuity from ignitor to chassis. |
14 | 16023522 | ©2004 Maytag Services |