Conversion Instructions (Models AGR4400AD*, AGR4412AD*, CG31400AD*, CG31600AD*, CGR1110AD*, CGR1415AD*, CGR1425AD*, CP31600AD*, MGR4451AD*, MGR4452AD*, PGR4420LD* )
Gas Conversion
General
All ranges are equipped with fixed orifices and with a convertible appliance pressure regulator. The unit model number plate states which gas it is adjusted for at the factory. To convert the unit to either Natural gas or LP gas will require the replacement of the orifice hoods, and the adjustment of the air shutters on the burners and adjustment of the appliance pressure regulator converter cap.
Inlet pressure to the appliance pressure regulator should be as follows for checking the appliance pressure regulator setting:
INLET PRESSURE IN | NATURAL | LP |
INCHES OF WATER COLUMN | GAS | GAS |
Minimum | 5 | 11 |
Maximum | 14 | 14 |
Appliance Pressure Regulator Conversion
The unit appliance pressure regulator must be set to match the type gas supply used. If converting from natural gas to LP gas, the appliance pressure regulator must be converted to regulate LP gas. If converting from LP gas to natural gas, the appliance pressure regulator must be converted to regulate natural gas.
The regulator can be accessed from behind the range, under the cooktop.
To convert the appliance pressure regulator from one gas to another, remove cap and forcibly snap out plastic plunger from bottom of cap. Turn plunger over and forcibly snap back in original location (Figure 1).
NOTE: Plunger MUST snap into position; the gas type you are converting to must be visible on lower side of plunger.
FIGURE 1
16023522 | ©2004 Maytag Services |